Literature DB >> 24841984

A method to achieve spatial linearity and uniform resolution at the edges of monolithic scintillation crystal detectors.

Ruud Vinke1, Craig S Levin.   

Abstract

We have performed Monte Carlo simulations of the scintillation light transport between adjacent monolithic LYSO crystals that are optically coupled together using coupling media of varying refractive index. The scintillation light from the crystals was read out by SiPM arrays from the large crystal face. Scintillation event positioning results show that this optical coupling technique preserves the shape of the light spread function near and across the interface between the two crystals in order to substantially reduce the edge-artifacts observed in monolithic scintillation crystals, while not degrading the timing performance.

Entities:  

Mesh:

Year:  2014        PMID: 24841984     DOI: 10.1088/0031-9155/59/12/2975

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Side readout of long scintillation crystal elements with digital SiPM for TOF-DOI PET.

Authors:  Jung Yeol Yeom; Ruud Vinke; Craig S Levin
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

2.  Evaluation of event position reconstruction in monolithic crystals that are optically coupled.

Authors:  M Morrocchi; W C J Hunter; A Del Guerra; T K Lewellen; P E Kinahan; L R MacDonald; M G Bisogni; R S Miyaoka
Journal:  Phys Med Biol       Date:  2016-11-03       Impact factor: 3.609

3.  Experimental validation of a rodent PET scanner prototype based on a single LYSO crystal tube.

Authors:  Marta Freire; Andrea Gonzalez-Montoro; Gabriel Cañizares; Ahmadreza Rezaei; Johan Nuyts; Stuart S Berr; Mark B Williams; Jose M Benlloch; Antonio J Gonzalez
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-11-01

4.  Modelling the transport of optical photons in scintillation detectors for diagnostic and radiotherapy imaging.

Authors:  Emilie Roncali; Mohammad Amin Mosleh-Shirazi; Aldo Badano
Journal:  Phys Med Biol       Date:  2017-10-04       Impact factor: 3.609

5.  Shared-photodetector readout to improve the sensitivity of positron emission tomography.

Authors:  Junwei Du; Peng Peng; Xiaowei Bai; Simon R Cherry
Journal:  Phys Med Biol       Date:  2018-10-09       Impact factor: 3.609

6.  Depth of interaction determination in monolithic scintillator with double side SiPM readout.

Authors:  Matteo Morrocchi; Giovanni Ambrosi; Maria Giuseppina Bisogni; Filippo Bosi; Marco Boretto; Piergiorgio Cerello; Maria Ionica; Ben Liu; Francesco Pennazio; Maria Antonietta Piliero; Giovanni Pirrone; Vasile Postolache; Richard Wheadon; Alberto Del Guerra
Journal:  EJNMMI Phys       Date:  2017-02-16

7.  Performance evaluation of side-by-side optically coupled monolithic LYSO crystals.

Authors:  Marta Freire; Sara Echegoyen; Andrea Gonzalez-Montoro; Filomeno Sanchez; Antonio J Gonzalez
Journal:  Med Phys       Date:  2022-06-21       Impact factor: 4.506

  7 in total