Literature DB >> 24841092

Highly sensitive and selective determination of bisphenol-A using peptide-modified gold electrode.

Jiao Yang1, Sung-Eun Kim1, Misuk Cho1, Ik-Keun Yoo2, Woo-Seok Choe3, Youngkwan Lee4.   

Abstract

Fast and accurate determination of bisphenol A (BPA) in varying matrices has become important in recent years. In this study, a cysteine-flanked heptapeptide sequence Cys-Lys-Ser-Leu-Glu-Asn-Ser-Tyr-Cys (CKSLENSYC), which is capable of recognizing BPA with high specificity, was isolated using a phage display technique. A novel electrochemical biosensor harnessing this affinity peptide as a BPA detection probe, was constructed and its performance was assessed. The formation of a self-assembled peptide monolayer on the gold electrode was confirmed by attenuated total reflection infrared spectroscopy (ATR-IR), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Following the exploration of the optimum sensing condition, differential pulse voltammetry (DPV) was used to determine the varying concentrations of BPA in the solution. The developed sensor conveyed excellent performance in view of sensing speed, sensitivity and selectivity by detecting BPA in less than 5 min with a broad dynamic detection range of 1-5000 nM of BPA, despite the presence of several interfering species, such as phenolic compounds and inorganic ions.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biosensor; Bisphenol A; Differential pulse voltammetry; Peptide; Self-assembled monolayer

Mesh:

Substances:

Year:  2014        PMID: 24841092     DOI: 10.1016/j.bios.2014.04.009

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

1.  Biosensor design using an electroactive label-based aptamer to detect bisphenol A in serum samples.

Authors:  Maryam Nazari; Soheila Kashanian; Ronak Rafipour; Kobra Omidfar
Journal:  J Biosci       Date:  2019-09       Impact factor: 1.826

2.  Label-free electrochemical impedance biosensor to detect human interleukin-8 in serum with sub-pg/ml sensitivity.

Authors:  R Sharma; S E Deacon; D Nowak; S E George; M P Szymonik; A A S Tang; D C Tomlinson; A G Davies; M J McPherson; C Wälti
Journal:  Biosens Bioelectron       Date:  2016-02-11       Impact factor: 10.618

Review 3.  Phage Display in the Quest for New Selective Recognition Elements for Biosensors.

Authors:  Riikka Peltomaa; Elena Benito-Peña; Rodrigo Barderas; María C Moreno-Bondi
Journal:  ACS Omega       Date:  2019-07-03

4.  Development of a new bisphenol A electrochemical sensor based on a cadmium(ii) porphyrin modified carbon paste electrode.

Authors:  Dhouha Jemmeli; Chadlia Mchiri; Chérif Dridi; Habib Nasri; Eithne Dempsey
Journal:  RSC Adv       Date:  2020-08-26       Impact factor: 4.036

5.  Sensitive Detection of Rosmarinic Acid Using Peptide-Modified Graphene Oxide Screen-Printed Carbon Electrode.

Authors:  Irina Georgiana Munteanu; Vasile Robert Grădinaru; Constantin Apetrei
Journal:  Nanomaterials (Basel)       Date:  2022-09-22       Impact factor: 5.719

Review 6.  Comparison of Electrochemical Immunosensors and Aptasensors for Detection of Small Organic Molecules in Environment, Food Safety, Clinical and Public Security.

Authors:  Benoit Piro; Shihui Shi; Steeve Reisberg; Vincent Noël; Guillaume Anquetin
Journal:  Biosensors (Basel)       Date:  2016-02-29
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.