Literature DB >> 24841090

Hand-drawn&written pen-on-paper electrochemiluminescence immunodevice powered by rechargeable battery for low-cost point-of-care testing.

Hongmei Yang1, Qingkun Kong1, Shaowei Wang1, Jinmeng Xu1, Zhaoquan Bian1, Xiaoxiao Zheng1, Chao Ma1, Shenguang Ge1, Jinghua Yu2.   

Abstract

In this paper, a pen-on-paper electrochemiluminescence (PoP-ECL) device was entirely hand drawn and written in commercially available crayon and pencil in turn for the first time, and a constant potential-triggered sandwich-type immunosensor was introduced into the PoP-ECL device to form a low-cost ECL immunodevice proof. Each PoP-ECL device contained a hydrophilic paper channel and two PoP electrodes, and the PoP-ECL device was produced as follows: crayon was firstly used to draw hydrophobic regions on pure cellulose paper to create the hydrophilic paper channels followed with a baking treatment, and then a 6B-type black pencil with low resistivity was applied for precision writing, as the PoP electrodes, across the hydrophilic paper channel. For further point-of-care testing, a portable, low-cost rechargeable battery was employed as the power source to provide constant potential to the PoP electrodes to trigger the ECL. Using Carbohydrate antigen 199 as model analyte, this PoP-ECL immunodevice showed a good linear response range from 0.01-200 U mL(-1) with a detection limit of 0.0055 U mL(-1), a high sensitivity and stability. The proposed PoP-ECL immunodevice could be used in point-of-care testing of other tumor markers for remote regions and developing countries.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Electrochemiluminescence immunosensor; Hand-drawn; Hand-written; Pen-on-paper; Point-of-care testing

Mesh:

Substances:

Year:  2014        PMID: 24841090     DOI: 10.1016/j.bios.2014.04.051

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

Review 1.  Biomarker detection for disease diagnosis using cost-effective microfluidic platforms.

Authors:  Sharma T Sanjay; Guanglei Fu; Maowei Dou; Feng Xu; Rutao Liu; Hao Qi; XiuJun Li
Journal:  Analyst       Date:  2015-11-07       Impact factor: 4.616

Review 2.  Paper and Other Fibrous Materials-A Complete Platform for Biosensing Applications.

Authors:  Domingo R Flores-Hernandez; Vivian J Santamaria-Garcia; Elda M Melchor-Martínez; Juan Eduardo Sosa-Hernández; Roberto Parra-Saldívar; Jaime Bonilla-Rios
Journal:  Biosensors (Basel)       Date:  2021-04-21

3.  Pencil It in: Exploring the Feasibility of Hand-Drawn Pencil Electrochemical Sensors and Their Direct Comparison to Screen-Printed Electrodes.

Authors:  Elena Bernalte; Christopher W Foster; Dale A C Brownson; Morgane Mosna; Graham C Smith; Craig E Banks
Journal:  Biosensors (Basel)       Date:  2016-08-29

Review 4.  Paper-Based Immunosensors with Bio-Chemiluminescence Detection.

Authors:  Maria Maddalena Calabretta; Martina Zangheri; Donato Calabria; Antonia Lopreside; Laura Montali; Elisa Marchegiani; Ilaria Trozzi; Massimo Guardigli; Mara Mirasoli; Elisa Michelini
Journal:  Sensors (Basel)       Date:  2021-06-24       Impact factor: 3.576

Review 5.  Electrochemiluminescence Biosensors Using Screen-Printed Electrodes.

Authors:  Emiliano Martínez-Periñán; Cristina Gutiérrez-Sánchez; Tania García-Mendiola; Encarnación Lorenzo
Journal:  Biosensors (Basel)       Date:  2020-09-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.