Literature DB >> 24841089

Ultrasensitive detection of mercury with a novel one-step signal amplified lateral flow strip based on gold nanoparticle-labeled ssDNA recognition and enhancement probes.

Mengya Zhu1, Ying Wang2, Yi Deng1, Li Yao1, Samuel B Adeloju3, Daodong Pan2, Feng Xue1, Yucheng Wu1, Lei Zheng4, Wei Chen5.   

Abstract

A novel one-step signal amplified lateral flow strip (SA-LFS) is described for direct ultrasensitive and on-site detection of Hg(2+) based on the specific recognition system of thymine-Hg(2+)-thymine using gold nanoparticles (AuNPs) as labeling tags. The signal was also amplified by hybridization induced dual labeling of AuNPs, which increased signal intensity of test line on strips. The presence of both probes on the LFS enabled both sensing and signal amplification to be achieved in a single step. The resulting SA-LFS is capable of rapid and ultrasensitive detection of Hg(2+) with LODs of 0.005 ppb and 0.0015 ppb by visual observation and quantitative analysis, respectively. At least 40-fold improvement in sensitivity of the traditional LFS was achieved through this signal amplification process. The successful application of the method to the determination of Hg(2+) in water sample is reported. The proposed signal amplification process may also be applicable to other LFS-based methods.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Food safety; Gold nanoparticles; Hg(2+) detection; Lateral flow strip; Signal amplification

Mesh:

Substances:

Year:  2014        PMID: 24841089     DOI: 10.1016/j.bios.2014.04.049

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

1.  Detection and imaging of Hg(II) in vivo using glutathione-functionalized gold nanoparticles.

Authors:  Gufeng Li; Shaoqing Li; Rui Wang; Min Yang; Lizhu Zhang; Yanli Zhang; Wenrong Yang; Hongbin Wang
Journal:  Beilstein J Nanotechnol       Date:  2022-06-23       Impact factor: 3.272

2.  Lateral Flow Test for Visual Detection of Multiple MicroRNAs.

Authors:  Wanli Zheng; Li Yao; Jun Teng; Chao Yan; Panzhu Qin; Guodong Liu; Wei Chen
Journal:  Sens Actuators B Chem       Date:  2018-03-20       Impact factor: 7.460

3.  Signal-Amplified Lateral Flow Test Strip for Visual Detection of Cu2.

Authors:  Yulong Wang; Limin Wang; Juanjuan Xue; Jinbo Dong; Jia Cai; Xiude Hua; Minghua Wang; Cunzheng Zhang; Fengquan Liu
Journal:  PLoS One       Date:  2017-01-10       Impact factor: 3.240

4.  Development a stacking pad design for enhancing the sensitivity of lateral flow immunoassay.

Authors:  Tsung-Ting Tsai; Tse-Hao Huang; Chung-An Chen; Natalie Yi-Ju Ho; Yi-Ju Chou; Chien-Fu Chen
Journal:  Sci Rep       Date:  2018-11-23       Impact factor: 4.379

Review 5.  Recent advances in sensitivity enhancement for lateral flow assay.

Authors:  Yulin Deng; Hao Jiang; Xiaoqiong Li; Xuefei Lv
Journal:  Mikrochim Acta       Date:  2021-10-13       Impact factor: 5.833

6.  Red Zn2SiO4:Eu3+ and Mg2TiO4:Mn4+ nanophosphors for on-site rapid optical detections: Synthesis and characterization.

Authors:  Su-Hua Yang; Hao-Yu Zhang; Chih-Chia Huang; Yi-Yan Tsai; Shun-Ming Liao
Journal:  Appl Phys A Mater Sci Process       Date:  2021-07-10       Impact factor: 2.584

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.