Literature DB >> 24840413

Electrochemiluminescence recovery-based aptasensor for sensitive Ochratoxin A detection via exonuclease-catalyzed target recycling amplification.

Mengli Yang1, Bingying Jiang2, Jiaqing Xie3, Yun Xiang4, Ruo Yuan1, Yaqin Chai1.   

Abstract

Based on the recovery of the quantum dot (QD) electrochemiluminescence (ECL) and exonuclease-catalyzed target recycling amplification, the development of a highly sensitive aptasensor for Ochratoxin A (OTA) detection is described. The duplex DNA probes containing the biotin-modified aptamer are immobilized on a CdTe QD composite film-coated electrode. The presence of the OTA target leads to effective removal of the biotin-aptamers from the electrode surface via exonuclease-catalyzed recycling and reuse of OTA, which prevents the attachment of streptavidin-alkaline phosphatase (STV-ALP) through biotin-STV interaction. The electron transfer (ET) from the excited state CdTe QD ([CdTe](⁎)) to the electro-oxidized species of the enzymatic product of ALP during the potential scan is thus inhibited and the QD ECL emission is restored for quantitative OTA detection. Due to the exonuclease-catalyzed target recycling amplification, the inhibition effect of ET is significantly enhanced to achieve sensitive detection of OTA down to 0.64 pg mL(-1). The proposed method is selective for OTA and can be used to monitor OTA in real red wine samples. Our developed ECL recovery-based aptasensor thus offers great potential for the development of new ECL sensing platforms for various target analytes.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Aptamer; Electrochemiluminescence; Exonuclease; Ochratoxin A; Quantum dots

Mesh:

Substances:

Year:  2014        PMID: 24840413     DOI: 10.1016/j.talanta.2014.02.061

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

Review 1.  A review on recent developments in optical and electrochemical aptamer-based assays for mycotoxins using advanced nanomaterials.

Authors:  K Yugender Goud; K Koteshwara Reddy; M Satyanarayana; Shekher Kummari; K Vengatajalabathy Gobi
Journal:  Mikrochim Acta       Date:  2019-12-07       Impact factor: 5.833

Review 2.  Recent Advances for the Detection of Ochratoxin A.

Authors:  Tai Hwan Ha
Journal:  Toxins (Basel)       Date:  2015-12-04       Impact factor: 4.546

3.  The determination of Ochratoxin A based on the electrochemical aptasensor by carbon aerogels and methylene blue assisted signal amplification.

Authors:  Min Wei; Wenyang Zhang
Journal:  Chem Cent J       Date:  2018-04-25       Impact factor: 4.215

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.