Introducing a new method for evaluation of the interaction between an antigen and an antibody: single frequency impedance analysis for biosensing systems.

Burcu Özcan1, Burçak Demirbakan1, Gülden Yeşiller1, Mustafa Kemal Sezgintürk2.   

Abstract

This paper illustrates the application of an antibody, anti-parathyroid hormone (anti-PTH), as a bioreceptor in a biosensor system for the first time, and demonstrates how this biosensor can be used in parathyroid hormone (PTH) determination. The interaction between the biosensor and parathyroid hormone was firstly investigated by a novel electrochemical method, single frequency impedance analysis. The biosensor was based on the gold electrode modified by cysteine self-assembled monolayers. Anti-PTH was covalently immobilized onto cysteine layer by using an EDC/NHS couple. The immobilization of anti-PTH was monitored by cyclic voltammetry and electrochemical impedance spectroscopy techniques. The performance of the biosensor was evaluated in terms of linearity, sensitivity, repeatability and reproducibility, after a few important optimization studies were carried out. In particular, parathyroid hormone was detected within a linear range of 10-60 fg/mL. Kramers-Kronig transform was also performed on the impedance data. The specificity of the biosensor was also evaluated. The biosensor was validated by using a complementary reference technique. Lastly the developed biosensor was used to monitor PTH levels in artificial serum samples.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Anti-parathyroid hormone; Biomarker; Biosensor; Parathyroid hormone; Parathyroidism; Single frequency impedance

Mesh:

Substances:

Year:  2014        PMID: 24840408     DOI: 10.1016/j.talanta.2014.02.067

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Static and Dynamic Measurement of Dopamine Adsorption in Carbon Fiber Microelectrodes Using Electrochemical Impedance Spectroscopy.

Authors:  Nilka Rivera-Serrano; Miraida Pagan; Joanisse Colón-Rodríguez; Christian Fuster; Román Vélez; Jose Almodovar-Faria; Carlos Jiménez-Rivera; Lisandro Cunci
Journal:  Anal Chem       Date:  2018-01-04       Impact factor: 6.986

2.  A direct and simple immobilization route for immunosensors by CNBr activation for covalent attachment of anti-leptin: obesity diagnosis point of view.

Authors:  İnci Uludağ; Mustafa Kemal Sezgintürk
Journal:  3 Biotech       Date:  2022-01-03       Impact factor: 2.406

3.  An ultrasensitive and disposable electrochemical aptasensor for prostate-specific antigen (PSA) detection in real serum samples.

Authors:  Canan Özyurt; İnci Uludağ; Mustafa Kemal Sezgintürk
Journal:  Anal Bioanal Chem       Date:  2022-09-26       Impact factor: 4.478