Literature DB >> 24837981

Dynamic volumetric CT angiography for the detection and classification of endoleaks: application of cine imaging using a 320-row CT scanner with 16-cm detectors.

Yuya Koike1, Kazufumi Ishida2, Soichiro Hase3, Yasuyuki Kobayashi4, Jun-Ichi Nishimura3, Motoshige Yamasaki3, Norifumi Hosaka3.   

Abstract

PURPOSE: To assess the feasibility and diagnostic performance of dynamic volumetric computed tomography (CT) angiography with large-area detectors in the detection and classification of endoleaks after endovascular aneurysm repair (EVAR).
MATERIALS AND METHODS: Low-dose dynamic volumetric CT angiography performed with the patient in Fowler position was used to scan the entire stent graft with a 16-cm-area detector during the first follow-up examination after EVAR. There were 39 consecutive patients (36 men and 3 women; mean age, 74 y ± 8.7) examined with approximately 14-20 intermittent scans (temporal resolution, 2 s; scan range, 160 mm). The effective radiation dose, image quality, interobserver and intraobserver agreement for endoleak detection, and time delay between peak enhancement of the aorta and endoleaks were evaluated.
RESULTS: All examinations with the patient in Fowler position enabled the entire stent graft to be scanned and were rated as diagnostic. The mean effective radiation dose was 13.1 mSv. Endoleaks were detected in eight patients (type Ia, n = 1; type II, n = 6; type III, n = 1). Interobserver agreement (κ = 0.794) and intraobserver agreement (κ = 1.00) for detection of endoleaks were excellent. The mean time delay between peak enhancement of the aorta and the endoleaks was significantly less for type I/III endoleaks (2.0 s ± 0) compared with type II endoleaks (5.3 s ± 1.0; P < .001).
CONCLUSIONS: Low-dose dynamic volumetric CT angiography performed with the patient in Fowler position is feasible after EVAR. Dynamic information, including cine imaging, the timing of peak enhancement, and the Hounsfield units index, is useful in detecting and classifying endoleaks.
Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 24837981     DOI: 10.1016/j.jvir.2014.03.019

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  7 in total

Review 1.  [Endovascular aortic repair of endoleaks : Diagnosis, treatment, and outcomes].

Authors:  Sven Rudolf Hauck; Rüdiger Schernthaner; Theresa-Marie Dachs; Maximilian Kern; Martin Funovics
Journal:  Radiologie (Heidelb)       Date:  2022-06-23

2.  Four-dimensional noise reduction using the time series of medical computed tomography datasets with short interval times: a static-phantom study.

Authors:  Tatsuya Nishii; Atsushi K Kono; Wakiko Tani; Erina Suehiro; Noriyuki Negi; Satoru Takahashi; Kazuro Sugimura
Journal:  PeerJ       Date:  2016-02-09       Impact factor: 2.984

3.  Dynamic Volumetric Computed Tomography Angiography Is a Preferred Method for Unclassified Endoleaks by Conventional Computed Tomography Angiography After Endovascular Aortic Repair.

Authors:  Kai Hou; Ting Zhu; Wei Zhang; Mengsu Zeng; Daqiao Guo; Weiguo Fu; Yi Si
Journal:  J Am Heart Assoc       Date:  2019-04-16       Impact factor: 5.501

4.  Quantitative analysis of dynamic computed tomography angiography for the detection of endoleaks after abdominal aorta aneurysm endovascular repair: A feasibility study.

Authors:  Georg Apfaltrer; Francesco Lavra; U Joseph Schoepf; Marco Scarabello; Ricardo Yamada; Marly van Assen; Akos Varga-Szemes; Brian E Jacobs; Maximilian J Bauer; William T Greenberg; Marcelo Guimaraes; Luca Saba; Carlo N De Cecco
Journal:  PLoS One       Date:  2021-01-07       Impact factor: 3.240

5.  High-pitch, low-voltage and low-iodine-concentration CT angiography of aorta: assessment of image quality and radiation dose with iterative reconstruction.

Authors:  Yanguang Shen; Zhonghua Sun; Lei Xu; Yu Li; Nan Zhang; Zixu Yan; Zhanming Fan
Journal:  PLoS One       Date:  2015-02-02       Impact factor: 3.240

Review 6.  MRI in Chronic Aortic Dissection: A Systematic Review and Future Directions.

Authors:  Andrew G Sherrah; Stuart M Grieve; Richmond W Jeremy; Paul G Bannon; Michael P Vallely; Rajesh Puranik
Journal:  Front Cardiovasc Med       Date:  2015-02-19

7.  Prospective, single UK centre, comparative study of the predictive values of contrast-enhanced ultrasound compared to time-resolved CT angiography in the detection and characterisation of endoleaks in high-risk patients undergoing endovascular aneurysm repair surveillance: a protocol.

Authors:  Iain Nicholas Roy; Tze Yuan Chan; Gabriela Czanner; Steve Wallace; Srinivasa Rao Vallabhaneni
Journal:  BMJ Open       Date:  2018-04-03       Impact factor: 2.692

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.