Literature DB >> 24836753

Application of a heterogeneous immunoassay for the quality control testing of release-active forms of diclofenac.

Michael Pschenitza1, Elena S Gavrilova2, Sergey А Tarasov3, Dietmar Knopp4, Reinhard Niessner5, Oleg I Epstein6.   

Abstract

We report on a specially designed diclofenac-ELISA for the determination of diclofenac in the presence of release-active forms of diclofenac in lactose dissolved in water solutions according to a predefined schedule in single-blind experiments. In accordance with the objective of this project, a number of experiments were conducted to determine the optimal ELISA conditions for detecting potential modulatory effects of release-active forms of diclofenac depending on their ability to affect the binding of diclofenac to anti-diclofenac antibodies. As a feature, the diclofenac antibodies were previously incubated with manufactured pharmaceutical samples containing release-active forms of diclofenac or placebo. For comparison of the sample types, measured in ELISA optical densities were chosen. For statistic analysis, Student's two-sample t-test and single-factor ANOVA were applied. The extremely low concentrations of diclofenac of 0.01, 0.05 and 0.1 ng mL(-1) seem most appropriate for routine assay performance. The source of diclofenac used for standard solution preparation is not important but it could be important as the source of diclofenac for release active form of diclofenac preparation. As an outcome, the ELISA appeared to be suitable for the detection of the modifying effects of release-active forms of diclofenac toward the pharmaceutical substance in vitro.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Diclofenac derivatives; ELISA; Quality control; Release activity

Mesh:

Substances:

Year:  2014        PMID: 24836753     DOI: 10.1016/j.intimp.2014.04.029

Source DB:  PubMed          Journal:  Int Immunopharmacol        ISSN: 1567-5769            Impact factor:   4.932


  2 in total

1.  Use of Piezoelectric Immunosensors for Detection of Interferon-Gamma Interaction with Specific Antibodies in the Presence of Released-Active Forms of Antibodies to Interferon-Gamma.

Authors:  Elena Don; Olga Farafonova; Suzanna Pokhil; Darya Barykina; Marina Nikiforova; Darya Shulga; Alena Borshcheva; Sergey Tarasov; Tatyana Ermolaeva; Oleg Epstein
Journal:  Sensors (Basel)       Date:  2016-01-20       Impact factor: 3.576

2.  Fluorescence polarization immunoassay for the determination of diclofenac in wastewater.

Authors:  Anna Raysyan; Robin Moerer; Bianca Coesfeld; Sergei A Eremin; Rudolf J Schneider
Journal:  Anal Bioanal Chem       Date:  2020-11-25       Impact factor: 4.142

  2 in total