Comparative study of three methods of estimation of creatinine clearance in critically ill patients.

V Blasco1, F Antonini1, L Zieleskiewicz1, E Hammad1, J Albanèse1, C Martin1, M Leone2.   

Abstract

BACKGROUND: At the bedside, the reference method for creatinine clearance determination is based on the measurement of creatinine concentrations in urine and serum (mCrCl). Several models are available to calculate the creatinine clearance from the serum creatinine concentration. This observational survey aimed at testing the hypothesis that the proposed equations are unreliable to determine accurate creatinine clearance in patients admitted to intensive care unit (ICU).
METHOD: Creatinine clearance was determined by the use of mCrCl. Then, we compared three equations: Cockcroft-Gault (CG), Simplified Modification of Diet in Renal Disease (MDRDs), and Chronic Kidney Disease Epidemiology (CKD-EPI) in 156 consecutive patients within the first 24hours after ICU admission. We tested the hypothesis that the three equations were equivalent. The agreement between the three equations was evaluated by linear regression and Bland and Altman analysis.
RESULTS: Bland and Altman analysis showed similar agreement between the three equations. The biases and precisions were -4.8±51, -1.3±50, and 8.2±44 for CG, MDRDs, and CKD-EPI equations, respectively (P>0.05). The precisions were similar for the three equations (P>0.05). The percentages of outliers at ±30% were 44%, 45%, and 49% for CG, MDRDs, and CKD-EPI, respectively (P>0.05).
CONCLUSION: Regarding the high percentage of outliers, the use of these equations cannot be recommended in ICU patients.
Copyright © 2014 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier SAS. All rights reserved.

Entities:  

Keywords:  Clairance; Clearance; Creatinine; Créatinine; Equations; Renal; Rénal; Équations

Mesh:

Substances:

Year:  2014        PMID: 24835538     DOI: 10.1016/j.annfar.2014.04.005

Source DB:  PubMed          Journal:  Ann Fr Anesth Reanim        ISSN: 0750-7658


  2 in total

1.  Role of an electronic antimicrobial alert system in intensive care in dosing errors and pharmacist workload.

Authors:  Barbara O M Claus; Kirsten Colpaert; Kristof Steurbaut; Filip De Turck; Dirk P Vogelaers; Hugo Robays; Johan Decruyenaere
Journal:  Int J Clin Pharm       Date:  2015-02-10

2.  Correlation of Measured and Estimated Creatinine Clearance in Hospitalized Elderly Patients: A Retrospective Cohort Study.

Authors:  Rachel I Lavelle; Austin R Brown; Anthony Gerlach
Journal:  Hosp Pharm       Date:  2020-05-17
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.