Literature DB >> 2483269

Amniotic fluid acetylcholinesterase measurement in the prenatal diagnosis of open neural tube defects. Second report of the Collaborative Acetylcholinesterase Study.

N Wald1, H Cuckle, K Nanchahal.   

Abstract

Seventeen centres from Australia, Britain, France, and the United States collaborated in a study to compare amniotic fluid acetylcholinesterase (AChE) determination by gel electrophoresis and amniotic fluid alpha-fetoprotein (AFP) measurement as diagnostic tests for open neural tube defects. The study was based on 32,642 women with singleton pregnancies (including 428 with open spina bifida and 238 with anencephaly) who had an amniocentesis at 13-24 weeks' gestation. The AChE test yielded a detection rate for open spina bifida of 99 per cent (95 per cent confidence interval 98-100 per cent), 98 per cent for anencephaly (95 per cent confidence interval 96-100 per cent), and a false-positive rate of 0.34 per cent (95 per cent confidence interval 0.28-0.40 per cent) excluding miscarriages, intrauterine death, and serious fetal abnormalities. The false-positive rate was 0.30 per cent among the 13 centres that used a specific AChE inhibitor in the test. Comparable rates for the AFP test were less favourable. (For example, the open spina bifida detection rate was 90 per cent and the false-positive rate was 0.46 per cent using the cut-off levels specified in the U.K. Collaborative AFP Study.) The AChE false-positive rate was lower in samples that were not bloodstained (0.16 per cent) than in those that were (2.4 per cent). It was higher in women who had an amniocentesis on account of a raised maternal serum AFP level (0.56 per cent) than in those who had one for other reasons (0.29 per cent). The best results were obtained by a combination of the two tests, an effective and economical policy being to perform the AFP measurement on all amniotic fluid samples and an AChE test on samples with AFP levels greater than or equal to 2.0 multiples of the normal median (about 5 per cent of all samples). Using this policy, the open spina bifida detection rate was 96 per cent and the false-positive rate was 0.14 per cent (0.06 per cent for samples that were not bloodstained and 1.2 per cent for those that were; 0.40 per cent for women with raised serum AFP levels and 0.09 per cent for other women). This policy offers a useful improvement to the prenatal diagnosis of open spina bifida.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2483269     DOI: 10.1002/pd.1970091202

Source DB:  PubMed          Journal:  Prenat Diagn        ISSN: 0197-3851            Impact factor:   3.050


  4 in total

1.  Isolation of Human Neural Stem Cells from the Amniotic Fluid with Diagnosed Neural Tube Defects.

Authors:  Yu-Jen Chang; Hong-Lin Su; Lee-Feng Hsu; Po-Jui Huang; Tzu-Hao Wang; Fu-Chou Cheng; Li-Wen Hsu; Ming-Song Tsai; Chih-Ping Chen; Yao-Lung Chang; An-Shine Chao; Shiaw-Min Hwang
Journal:  Stem Cells Dev       Date:  2015-06-04       Impact factor: 3.272

Review 2.  Prevention of chronic kidney disease in spina bifida.

Authors:  Guido Filler; Mireille Gharib; Shelley Casier; Petra Lödige; Jochen H H Ehrich; Sumit Dave
Journal:  Int Urol Nephrol       Date:  2011-01-13       Impact factor: 2.370

3.  Prenatal biochemical screening for neural tube defects.

Authors:  Françoise Muller
Journal:  Childs Nerv Syst       Date:  2003-07-12       Impact factor: 1.475

4.  SELDI-TOF-MS proteomic profiling of serum, urine, and amniotic fluid in neural tube defects.

Authors:  Zhenjiang Liu; Zhengwei Yuan; Qun Zhao
Journal:  PLoS One       Date:  2014-07-23       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.