| Literature DB >> 24831394 |
Maria Enedina Aquino Scuarcialupi1, Danilo Cortozi Berton1, Priscila Kessar Cordoni1, Selma Denis Squassoni1, Elie Fiss1, José Alberto Neder1.
Abstract
OBJECTIVE: To investigate the modulatory effects that dynamic hyperinflation (DH), defined as a reduction in inspiratory capacity (IC), has on exercise tolerance after bronchodilator in patients with COPD.Entities:
Mesh:
Substances:
Year: 2014 PMID: 24831394 PMCID: PMC4083636 DOI: 10.1590/s1806-37132014000200003
Source DB: PubMed Journal: J Bras Pneumol ISSN: 1806-3713 Impact factor: 2.624
Figure 1Study design. BD: bronchodilator; CPET: cardiopulmonary exercise testing; and R: randomization.
Figure 2Change in inspiratory capacity bronchodilator-placebo (BD-PL) at rest (in A) and at isotime of exercise at constant speed (in B) in the groups of patients with dynamic hyperinflation (DH+) and without dynamic hyperinflation (DH-). *p < 0.05; intragroup BD-PL difference. †Intergroup BD-PL difference.
Measurements taken before, during, and after constant-load exercise performed after placebo or bronchodilator use in the groups of patients with and without dynamic hyperinflation during exercise.a
| Variables | Groups | ||||
|---|---|---|---|---|---|
| DH+ | DH- | ||||
| (n = 21) | (n = 9) | ||||
| PL | BD | PL | BD | ||
| Spirometry | |||||
| FEV1, L | 1.01 ± 0.26 | 1.21 ± 0.36 | 1.32 ± 0.41* | 1.55 ± 0.45* | |
| FEV1, % of predicted | 39 ± 11 | 46 ± 13 | 49 ± 16* | 57 ± 15* | |
| FVC, L | 2.18 ± 0.46 | 2.52 ± 0.59 | 2.44 ± 0.43 | 2.77 ± 0.52 | |
| FVC, % of predicted | 63 ± 11 | 72 ± 13 | 70 ± 18 | 80 ± 19 | |
| Resting IC, L | 1.83 ± 0.57 | 1.89 ± 0.52 | 1.47 ± 0.32* | 1.85 ± 0.44**,*** | |
| Isotime of exercise | |||||
| IC, L | 1.50 ± 0.45 | 1.70 ± 0.51 | 1.61 ± 0.28 | 1.78 ± 0.28** | |
| Δ IC isotime-rest, L | -0.32 ± 0.22 | -0.19 ± 0.18** | 0.14 ± 0.23* | -0.06 ± 0.26**,*** | |
| Dyspneab | 9.0 (7.0-10) | 4.5 (2.0-10)** | 4.0 (2.0-7.0)* | 3.0 (1.0-7.0)*** | |
| Δ dyspnea BD-PLb | -3.5 (-6.0 to -1.0) | -1.0 (-3.0 to -4.0)*** | |||
| Leg fatigueb | 7 (3-10) | 5 (2-10) | 5 (3-8)* | 5 (1-7) | |
| Δ leg fatigue BD-PLb | -1.5 (-7.0 to -5.0) | -2.0 (-3.0 to -4.0) | |||
| End of exercise | |||||
| Tlim, s | 423 ± 170 | 542 ± 258** | 654 ± 255* | 783 ± 261*,** | |
| Dyspneab | 9.0 (7.0-10) | 7.5 (1.0-10) | 4.5 (2.0-7.0)* | 4.5 (1.0-9.0) | |
| Leg fatigueb | 7.0 (7.0-10) | 7.0 (1.0-10) | 5.0 (3.0-8.0)* | 5.5 (0.0-9.0) | |
| SpO2, % | 91 ± 6 | 92 ± 5 | 87 ± 8 | 89 ± 9 | |
: placebo
: bronchodilator
: inspiratory capacity
Figure 3Bronchodilator/placebo (BD-PL) change in exercise tolerance (Tlim) in the patients (dashed lines) with dynamic hyperinflation (in A) and without dynamic hyperinflation (in B). The solid lines represent the group means. *p < 0.05; intragroup difference.
Figura 1Delineamento do estudo. BD: broncodilatador; TECP: teste de exercício cardiopulmonar: e R: randomização.
Medidas antes, durante e após exercício de carga constante com o uso de placebo ou de broncodilatador nos grupos de pacientes com e sem hiperinsuflação dinâmica ao esforço.a
| Variáveis | Grupos | |||
|---|---|---|---|---|
| HD+ | HD- | |||
| (n = 21) | (n = 9) | |||
| PL | BD | PL | BD | |
| Espirometria | ||||
| VEF1, L | 1,01 ± 0,26 | 1,21 ± 0,36 | 1,32 ± 0,41* | 1,55 ± 0,45* |
| VEF1, % previsto | 39 ± 11 | 46 ± 13 | 49 ± 16* | 57 ± 15* |
| CVF, L | 2,18 ± 0,46 | 2,52 ± 0,59 | 2,44 ± 0,43 | 2,77 ± 0,52 |
| CVF, % previsto | 63 ± 11 | 72 ± 13 | 70 ± 18 | 80 ± 19 |
| CI repouso, L | 1,83 ± 0,57 | 1,89 ± 0,52 | 1,47 ± 0,32* | 1,85 ± 0,44**,*** |
| Exercício, isotempo | ||||
| CI, L | 1,50 ± 0,45 | 1,70 ± 0,51 | 1,61 ± 0,28 | 1,78 ± 0,28** |
| Δ CI isotempo-repouso, L | -0,32 ± 0,22 | -0,19 ± 0,18** | 0,14 ± 0,23* | -0,06 ± 0,26**,*** |
| Dispneiab | 9,0 (7,0-10) | 4,5 (2,0-10)** | 4,0 (2,0-7,0)* | 3,0 (1,0-7,0)*** |
| Δ Dispneia BD-PLb | -3,5 (-6,0 a -1,0) | -1,0 (-3,0 a -4,0)*** | ||
| Fadiga MMIIb | 7 (3-10) | 5 (2-10) | 5 (3-8)* | 5 (1-7) |
| Δ Fadiga em MMII BD-PLb | -1,5 (-7,0 a -5,0) | -2,0 (-3,0 a -4,0) | ||
| Exercício, final | ||||
| Tlim, s | 423 ± 170 | 542 ± 258** | 654 ± 255* | 783 ± 261*,** |
| Dispneiab | 9,0 (7,0-10) | 7,5 (1,0-10) | 4,5 (2,0-7,0)* | 4,5 (1,0-9,0) |
| Fadiga MMIIb | 7,0 (7,0-10) | 7,0 (1,0-10) | 5,0 (3,0-8,0)* | 5,5 (0,0-9,0) |
| SpO2, % | 91 ± 6 | 92 ± 5 | 87 ± 8 | 89 ± 9 |
: placebo
: broncodilatador
: capacidade inspiratória
: membros inferiores
: tempo de tolerância ao exercício
Valores apresentados em média ± dp, exceto onde indicado
Valores apresentados em mediana (intervalo interquartílico). Escala modificada de Borg
p < 0,05: variação intergrupos num dado momento (PL ou BD)
p < 0,05: variação intrassujeitos (pré vs. pós-BD)
p < 0,05 variação intergrupos (pré vs. pós-BD).
Figura 2Variação da capacidade inspiratória broncodilatador-placebo (BD-PL) no repouso (em A) e no isotempo do exercício de velocidade constante (em B) nos grupos com hiperinsuflação dinâmica (HD+) e sem hiperinsuflação dinâmica (HD-). *p < 0,05; diferença BD-PL intragrupo. †Diferença intergrupos BD-PL.
Figura 3Variação broncodilatador-placebo (BD-PL) do tempo de tolerância ao exercício (Tlim) nos pacientes (linhas tracejadas) com hiperinsuflação dinâmica (em A) e sem hiperinsuflação dinâmica (em B). As linhas contínuas representam as médias dos grupos. *p < 0,05; diferença intragrupo.