Addition of benzalkonium chloride to self-adhesive resin-cements: some clinically relevant properties.

Serra Oguz Ahmet1, M Murat Mutluay, Zelal Seyfioglu Polat, Roda Seseogullari Dirihan, Bulent Bek, Arzu Tezvergil-Mutluay.   

Abstract

OBJECTIVE: The clinical survival rates of the adhesive restorations are limited due to the deterioration of resin-dentin bonds over time, partly due to the endogenous enzymatic activity of dentin. Recently, benzalkonium chloride (BAC) has been shown to effectively inhibit endogenous protease activity of dentin. This study evaluated the effect of different concentrations of benzalkonium chloride (BAC) on the degree of conversion (DC), vickers hardness (VH), setting time (ST) and biaxial flexural strength (FS) of two self-adhesive resin luting cements (RC).
METHODS: Two RC SpeedCEM (Ivoclar-Vivadent) and BisCem (Bisco) were modified by addition of 0.1, 0.5, 1, 1.5, 2 wt% BAC. The luting cements without the addition of BAC served as control. The DC (FT-IR/ATR from the bottom of the resin disc), vickers hardness (from top and bottom of the light-cured specimen), setting time (ISO 4049) and biaxial flexural strength (0.6 × 6 mm discs) of the specimens were tested. Data were analyzed using ANOVA and Tukeys HSD.
RESULTS: DC results were in the range of 70-80%, with some significant changes in BisCem (p < 0.05). VH values of both materials increased significantly compared to control, with no significant change as the BAC percentage increases. BAC addition influenced the ST differently for both materials. For BisCem, a gradual decrease (p < 0.05) was observed whereas, for SpeedCEM, a gradual increase was observed until 1% BAC (p < 0.05). For FS values, a gradual decrease was observed for both materials with increased amounts of BAC (p < 0.05), compared to the control group.
CONCLUSIONS: BAC addition of up to 1% seems to be acceptable considering the properties tested. Clinical significance. Incorporation of benzalkonium chloride to self-adhesive resin luting cements during the mixing procedure does not significantly affect the degree of conversion or flexural strength of the luting agent and may be a good option to improve the durability of adhesive interface.

Entities:  

Keywords:  benzalkonium chloride; monomer conversion; self-adhesive cements; setting time; vickers hardness

Mesh:

Substances:

Year:  2014        PMID: 24823935     DOI: 10.3109/00016357.2014.913307

Source DB:  PubMed          Journal:  Acta Odontol Scand        ISSN: 0001-6357            Impact factor:   2.331


  4 in total

1.  Antimicrobial efficacy and mechanical properties of BAC-modified hard and soft denture liners.

Authors:  Pinar Altinci; Murat Mutluay; Eva Söderling; Arzu Tezvergil-Mutluay
Journal:  Odontology       Date:  2017-03-20       Impact factor: 2.634

Review 2.  Should local drug delivery systems be used in dentistry?

Authors:  Joana Vieira Costa; Jaime Portugal; Cristina Bettencourt Neves; Ana F Bettencourt
Journal:  Drug Deliv Transl Res       Date:  2021-09-20       Impact factor: 4.617

3.  Construction and properties of the antibacterial epitaxial transition layer on a zirconia ceramic surface.

Authors:  Xiuju Liu; Qiuli Cheng; Yanlin Zhu; Shiyang Yu; Yanyan Hou; Zhanchen Cui; Song Zhu
Journal:  RSC Adv       Date:  2021-10-29       Impact factor: 4.036

4.  Long-Term Bond Strength of Two Benzalkonium Chloride-Modified Adhesive Systems to Eroded Dentin.

Authors:  Simon Flury; Adrian Lussi; Anne Peutzfeldt
Journal:  Biomed Res Int       Date:  2017-08-10       Impact factor: 3.411

  4 in total