Literature DB >> 24822117

The value of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry in identifying clinically relevant bacteria: a comparison with automated microbiology system.

Chunmei Zhou1, Bijie Hu1, Xuelian Zhang1, Shenglei Huang1, Yuzhang Shan1, Xiangru Ye1.   

Abstract

BACKGROUND: Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been developed as a new-type soft ionization mass spectrometry in the recent year. Increasing number of clinical microbiological laboratories consider it as an innovate approach for bacterial identification.
METHODS: A total of 876 clinical strains, comprising 52 species in 27 genus, were obtained from Fudan University Affiliated Zhongshan Hospital. We compared the identification accuracy of the Vitek MS system (bioMerieux, Marcy l'Etoile) to other conventional methods for bacterial identification. 16S rRNA gene sequencing was performed as a reference identification method in cases of discrepant results.
RESULTS: The Vitek MS system consistently produced accurate results within minutes of loading, while conventional methods required several hours to produce identification results. Among the 876 isolates, the overall performance of Vitek MS was significantly better than the conventional method both for correct species identification (830, 94.7% vs. 746, 85.2%, respectively, P=0.000).
CONCLUSIONS: Compared to traditional identification methods, MALDI-TOF MS is a rapid, accurate and economical technique to enhance the clinical value of microorganism identification.

Keywords:  Mass spectrometry; bacteria; identification

Year:  2014        PMID: 24822117      PMCID: PMC4015012          DOI: 10.3978/j.issn.2072-1439.2014.02.21

Source DB:  PubMed          Journal:  J Thorac Dis        ISSN: 2072-1439            Impact factor:   2.895


  13 in total

1.  Tuf gene sequence analysis has greater discriminatory power than 16S rRNA sequence analysis in identification of clinical isolates of coagulase-negative staphylococci.

Authors:  Sang Mee Hwang; Myoung Shin Kim; Kyoung Un Park; Junghan Song; Eui-Chong Kim
Journal:  J Clin Microbiol       Date:  2011-10-12       Impact factor: 5.948

2.  Comparison of two matrix-assisted laser desorption ionization-time of flight mass spectrometry methods with conventional phenotypic identification for routine identification of bacteria to the species level.

Authors:  Abdessalam Cherkaoui; Jonathan Hibbs; Stéphane Emonet; Manuela Tangomo; Myriam Girard; Patrice Francois; Jacques Schrenzel
Journal:  J Clin Microbiol       Date:  2010-02-17       Impact factor: 5.948

3.  Identification of clinical coagulase-negative staphylococci, isolated in microbiology laboratories, by matrix-assisted laser desorption/ionization-time of flight mass spectrometry and two automated systems.

Authors:  C Dupont; V Sivadon-Tardy; E Bille; B Dauphin; J L Beretti; A S Alvarez; N Degand; A Ferroni; M Rottman; J L Herrmann; X Nassif; E Ronco; E Carbonnelle
Journal:  Clin Microbiol Infect       Date:  2009-09-03       Impact factor: 8.067

4.  Comparative study using various methods for identification of Staphylococcus species in clinical specimens.

Authors:  F Layer; B Ghebremedhin; K-A Moder; W König; B König
Journal:  J Clin Microbiol       Date:  2006-08       Impact factor: 5.948

5.  Two-center collaborative evaluation of the performance of the BD Phoenix automated microbiology system for identification and antimicrobial susceptibility testing of Enterococcus spp. and Staphylococcus spp.

Authors:  Anne-Marie Fahr; Ulrich Eigner; Martina Armbrust; Alexandra Caganic; Giuseppe Dettori; Carlo Chezzi; Luca Bertoncini; Magda Benecchi; Maria Grazia Menozzi
Journal:  J Clin Microbiol       Date:  2003-03       Impact factor: 5.948

6.  Performance of matrix-assisted laser desorption ionization-time of flight mass spectrometry for identification of bacterial strains routinely isolated in a clinical microbiology laboratory.

Authors:  A Bizzini; C Durussel; J Bille; G Greub; G Prod'hom
Journal:  J Clin Microbiol       Date:  2010-03-10       Impact factor: 5.948

7.  Comparison of genotypic and phenotypic methods for species-level identification of clinical isolates of coagulase-negative staphylococci.

Authors:  E Heikens; A Fleer; A Paauw; A Florijn; A C Fluit
Journal:  J Clin Microbiol       Date:  2005-05       Impact factor: 5.948

Review 8.  [Bacterial identification based on protein mass spectrometry: A new insight at the microbiology of the 21st century].

Authors:  Patricia García; Fidel Allende; Paulette Legarraga; Marcos Huilcaman; Sandra Solari
Journal:  Rev Chilena Infectol       Date:  2012-06       Impact factor: 0.520

9.  High-throughput identification of bacteria and yeast by matrix-assisted laser desorption ionization-time of flight mass spectrometry in conventional medical microbiology laboratories.

Authors:  S Q van Veen; E C J Claas; Ed J Kuijper
Journal:  J Clin Microbiol       Date:  2010-01-06       Impact factor: 5.948

Review 10.  Pathogenic Escherichia coli.

Authors:  James B Kaper; James P Nataro; Harry L Mobley
Journal:  Nat Rev Microbiol       Date:  2004-02       Impact factor: 60.633

View more
  5 in total

1.  Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for the identification of beta-hemolytic streptococci.

Authors:  Chunmei Zhou; Lili Tao; Bijie Hu; Jian Ma; Xiangru Ye; Shenglei Huang; Yan Ma; Yuzhang Shan
Journal:  J Thorac Dis       Date:  2015-04       Impact factor: 2.895

2.  Matrix-assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF MS) for rapid identification of micro-organisms in the routine clinical microbiology laboratory.

Authors:  C Wattal; J K Oberoi; N Goel; R Raveendran; S Khanna
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2016-12-16       Impact factor: 3.267

Review 3.  Performance of the matrix-assisted laser desorption ionization time-of-flight mass spectrometry system for rapid identification of streptococci: a review.

Authors:  W-T Fan; T-T Qin; R-R Bi; H-Q Kang; P Ma; B Gu
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2017-01-23       Impact factor: 3.267

4.  Accuracy of matrix-assisted laser desorption ionization time-of-flight mass spectrometry for direct bacterial identification from culture-positive urine samples.

Authors:  Bin Sun; Wei Wang; Ping Ma; Bing Gu
Journal:  Ann Transl Med       Date:  2021-04

5.  Comparison of biomarker based Matrix Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry (MALDI-TOF MS) and conventional methods in the identification of clinically relevant bacteria and yeast.

Authors:  Ali Kassim; Valentin Pflüger; Zul Premji; Claudia Daubenberger; Gunturu Revathi
Journal:  BMC Microbiol       Date:  2017-05-25       Impact factor: 3.605

  5 in total