PURPOSE: Implant impressions and working models form integrated precision systems for registration and transmission of clinical data. The components of implant systems have a dimensional tolerance capable of introducing inaccuracies in the impression, thus in the prosthetic framework. This article aimed at comparing 2 repositioning impression techniques: one using impression copings (conventional technique) and the other using the final abutments as impression copings (interceptive technique).
MATERIALS AND METHODS: Two experimental models, one with 4 parallel implants and the other with 4 nonparallel implants, were used to make silicone impressions. Twenty impressions were made with the conventional technique, and a further 20 were made with the interceptive technique. Three-dimensional images acquired with a three-dimensional scanner were measured using a three-dimensional image analysis software, comparing models obtained from the impressions with the experimental models. Data were statistically analyzed by means of confidence intervals calculated with the mean (α = 0.05), descriptive (box plot), and bivariate analyses.
RESULTS: Statistic analysis highlighted significant differences among models obtained using both techniques: the interceptive technique generated working models with less distortion and variability.
CONCLUSIONS: For internal-connection implants, the interceptive technique provided significantly more precise working models than did the conventional technique.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24820709     DOI: 10.1097/SCS.0000000000000715

Source DB:  PubMed          Journal:  J Craniofac Surg        ISSN: 1049-2275            Impact factor:   1.046