Literature DB >> 24818199

Implications of implant framework misfit: a systematic review of biomechanical sequelae.

Jaafar Abduo, Roy B Judge.   

Abstract

PURPOSE: The objective of this study was to review all biomechanical investigations that have evaluated the implications of implant framework misfit with fixed prostheses.
MATERIALS AND METHODS: A detailed electronic search was conducted of PubMed (MEDLINE), Google Scholar, and Cochrane Library with the aid of Boolean operators to combine relevant key words. The search was confined to articles published in English through April 2013. The literature search was enlarged by manual searches of the peer-reviewed literature and the reference lists of the selected articles.
RESULTS: A total of 633 articles were retrieved from the initial search; however, only 28 articles met the determined inclusion criteria of the review. According to the study design, the selected articles were classified into two categories: laboratory studies (finite element analyses, actual model analyses, and screw stability analyses) and animal studies. The studies evaluated the effects of alterations in the magnitude and configuration of misfit, framework rigidity, type of retaining screws, and implant loading time. In addition to a lack of clear criteria of what constitutes an accurate implant framework fit, the biomechanical implications of framework misfit are unclear.
CONCLUSIONS: Although implant framework misfit alters the biomechanical situation, negative biomechanical sequelae could not be confirmed from the included studies. Biologically, bone resorption cannot develop as a result of framework misfit. From a mechanical perspective, the framework stresses and screw stresses and instability increase with misfit, but the clinical significance of this remains unclear.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24818199     DOI: 10.11607/jomi.3418

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  6 in total

Review 1.  The Prosthetic Influence and Biomechanics on Peri-Implant Strain: a Systematic Literature Review of Finite Element Studies.

Authors:  Julius Maminskas; Algirdas Puisys; Ritva Kuoppala; Aune Raustia; Gintaras Juodzbalys
Journal:  J Oral Maxillofac Res       Date:  2016-09-09

2.  Management of Buccal Screw Access Hole Positioning for Implant Fixed Complete Dentures: A Report of Two Patients and a Proposed Decision Tree.

Authors:  Fawaz Alzoubi
Journal:  Case Rep Dent       Date:  2021-12-21

Review 3.  New generation CAD-CAM materials for implant-supported definitive frameworks fabricated by using subtractive technologies.

Authors:  Pinar Cevik; Martin Schimmel; Burak Yilmaz
Journal:  Biomed Res Int       Date:  2022-03-02       Impact factor: 3.411

4.  Fit of cobalt-chromium implant frameworks before and after ceramic veneering in comparison with CNC-milled titanium frameworks.

Authors:  Per Svanborg; Victoria Stenport; Alf Eliasson
Journal:  Clin Exp Dent Res       Date:  2015-10-26

5.  Accuracy of digital impressions versus conventional impressions for 2 implants: an in vitro study evaluating the effect of implant angulation.

Authors:  Jaafar Abduo; Joseph E A Palamara
Journal:  Int J Implant Dent       Date:  2021-07-30

6.  Can transfer type and implant angulation affect impression accuracy? A 3D in vitro evaluation.

Authors:  Davide Farronato; Pietro Mario Pasini; Veronica Campana; Diego Lops; Lorenzo Azzi; Mattia Manfredini
Journal:  Odontology       Date:  2021-06-01       Impact factor: 2.634

  6 in total