Metrological assessment of a portable analyzer for monitoring the particle size distribution of ultrafine particles.

Luca Stabile1, Emanuele Cauda2, Sara Marini1, Giorgio Buonanno3.   

Abstract

Adverse health effects caused by worker exposure to ultrafine particles have been detected in recent years. The scientific community focuses on the assessment of ultrafine aerosols in different microenvironments in order to determine the related worker exposure/dose levels. To this end, particle size distribution measurements have to be taken along with total particle number concentrations. The latter are obtainable through hand-held monitors. A portable particle size distribution analyzer (Nanoscan SMPS 3910, TSI Inc.) was recently commercialized, but so far no metrological assessment has been performed to characterize its performance with respect to well-established laboratory-based instruments such as the scanning mobility particle sizer (SMPS) spectrometer. The present paper compares the aerosol monitoring capability of the Nanoscan SMPS to the laboratory SMPS in order to evaluate whether the Nanoscan SMPS is suitable for field experiments designed to characterize particle exposure in different microenvironments. Tests were performed both in a Marple calm air chamber, where fresh diesel particulate matter and atomized dioctyl phthalate particles were monitored, and in microenvironments, where outdoor, urban, indoor aged, and indoor fresh aerosols were measured. Results show that the Nanoscan SMPS is able to properly measure the particle size distribution for each type of aerosol investigated, but it overestimates the total particle number concentration in the case of fresh aerosols. In particular, the test performed in the Marple chamber showed total concentrations up to twice those measured by the laboratory SMPS-likely because of the inability of the Nanoscan SMPS unipolar charger to properly charge aerosols made up of aggregated particles. Based on these findings, when field test exposure studies are conducted, the Nanoscan SMPS should be used in tandem with a condensation particle counter in order to verify and correct the particle size distribution data. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2014.

Entities:  

Keywords:  Nanoscan SMPS; diesel particulate matter; dioctyl phthalate particles; laboratory SMPS; metrological assessment; occupational aerosol; particle size distribution; portable analyzer; total particle number concentration; ultrafine particles

Mesh:

Substances:

Year:  2014        PMID: 24817159     DOI: 10.1093/annhyg/meu025

Source DB:  PubMed          Journal:  Ann Occup Hyg        ISSN: 0003-4878


  4 in total

1.  A Miniature Aerosol Sensor for Detecting Polydisperse Airborne Ultrafine Particles.

Authors:  Chao Zhang; Dingqu Wang; Rong Zhu; Wenming Yang; Peng Jiang
Journal:  Sensors (Basel)       Date:  2017-04-22       Impact factor: 3.576

2.  Precision and Accuracy of a Direct-Reading Miniaturized Monitor in PM2.5 Exposure Assessment.

Authors:  Francesca Borghi; Andrea Spinazzè; Davide Campagnolo; Sabrina Rovelli; Andrea Cattaneo; Domenico M Cavallo
Journal:  Sensors (Basel)       Date:  2018-09-13       Impact factor: 3.576

3.  Performance evaluation of newly developed portable aerosol sizers used for nanomaterial aerosol measurements.

Authors:  Maromu Yamada; Mitsutoshi Takaya; Isamu Ogura
Journal:  Ind Health       Date:  2015-08-28       Impact factor: 2.179

4.  Comparison of four nanoparticle monitoring instruments relevant for occupational hygiene applications.

Authors:  Rikke Bramming Jørgensen
Journal:  J Occup Med Toxicol       Date:  2019-11-27       Impact factor: 2.646

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.