Literature DB >> 24815908

Mortality predicted by preinduction cerebral oxygen saturation after cardiac operation.

Xiumei Sun1, Jennifer Ellis2, Paul J Corso2, Peter C Hill2, Robert Lowery2, Fang Chen3, Joseph Lindsay4.   

Abstract

BACKGROUND: An intraoperative decline in regional cerebral oxygen saturation (rSO2) has been associated with postoperative injury to the central nervous system. Wide individual variation in steady-state cerebral oxygen saturation limits the clinical use of rSO2 to monitoring during anesthesia and surgical procedures. Recently, low preoperative rSO2 has been proposed as a predictor of adverse postoperative outcomes in cardiovascular operations. We compared the sensitivity and specificity of preinduction rSO2 as a predictor of adverse operative events and compared this to the widely accepted risk index developed by the Society for Thoracic Surgeons.
METHODS: 2,097 consecutive white patients who underwent cardiac operations from 2010 through 2012 were included. In 1,496 patients (group 1) the preinduction rSO2 was equal to or greater than 60%, whereas in the remaining 601 patients (group 2) it was below 60%. We compared the predictive accuracy of preinduction rSO2 with that of the STS mortality risk score by means of standard statistical techniques, including a receiver operating curve characteristic analysis.
RESULTS: Patients with a preinduction rSO2 below 60% had significantly higher STS mortality risk scores than did patients with an rSO2 equal to or greater than 60% (2.0 vs 4.0, p<0.001). Those with an rSO2 below 60% experienced higher operative mortality (p<0.001) and after adjustment this determination emerged as an independent predictor of increased mortality (p<0.001). Receiver operating characteristic curve analysis demonstrated that the rSO2 was slightly less accurate as a mortality predictor (area under the curve: 0.71 vs 0.85).
CONCLUSIONS: Measurement of rSO2 is considerably less complex than calculation of the STS score and is only slightly less accurate as a predictor of operative mortality. It may be useful when the STS mortality risk score cannot be calculated.
Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24815908     DOI: 10.1016/j.athoracsur.2014.03.025

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  7 in total

1.  An observational study of the optimal placement of a cerebral oximeter probe to avoid the frontal sinus in children.

Authors:  Eun-Hee Kim; Kyu-Young Song; In-Kyung Song; Ji-Hyun Lee; Young-Eun Jang; Hee-Soo Kim; Seo-Hee Lee; Jin-Tae Kim
Journal:  J Clin Monit Comput       Date:  2017-12-11       Impact factor: 2.502

2.  Intraoperative cerebral oxygenation, oxidative injury, and delirium following cardiac surgery.

Authors:  Marcos G Lopez; Pratik Pandharipande; Jennifer Morse; Matthew S Shotwell; Ginger L Milne; Mias Pretorius; Andrew D Shaw; L Jackson Roberts; Frederic T Billings
Journal:  Free Radic Biol Med       Date:  2016-12-27       Impact factor: 7.376

3.  Combined cerebral and somatic near-infrared spectroscopy oximetry monitoring during liver surgery: an observational and non-interventional study.

Authors:  Yves Collin; Tina Hu; André Denault; Annik Fortier; William Beaubien-Souligny; Réal Lapointe; Franck Vandenbroucke-Menu
Journal:  Korean J Anesthesiol       Date:  2022-01-20

4.  Cerebral oxygen saturation after multiple perioperative influential factors predicts the occurrence of postoperative cognitive dysfunction.

Authors:  Cheng Ni; Ting Xu; Nan Li; Yang Tian; Yongzheng Han; Qingsheng Xue; Min Li; Xiangyang Guo
Journal:  BMC Anesthesiol       Date:  2015-10-26       Impact factor: 2.217

5.  Tissue oximetry during cardiac surgery and in the cardiac intensive care unit: A prospective observational trial.

Authors:  Benjamin J Heller; Pranav Deshpande; Joshua A Heller; Patrick McCormick; Hung-Mo Lin; Ruiqi Huang; Gregory Fischer; Menachem M Weiner
Journal:  Ann Card Anaesth       Date:  2018 Oct-Dec

6.  Cerebral oxygen desaturation in patients with totally thoracoscopic ablation for atrial fibrillation: A prospective observational study.

Authors:  Guohui Li; Liqiao Yang; Yuan Sun; Sai'e Shen
Journal:  Medicine (Baltimore)       Date:  2020-04       Impact factor: 1.889

7.  Association between Cerebral Oxygen Saturation with Outcome in Cardiac Surgery: Brain as an Index Organ.

Authors:  Youn Yi Jo; Jae-Kwang Shim; Sarah Soh; Sungmin Suh; Young Lan Kwak
Journal:  J Clin Med       Date:  2020-03-19       Impact factor: 4.241

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.