Literature DB >> 24809665

Technical considerations on the validity of blood oxygenation level-dependent-based MR assessment of vascular deoxygenation.

Nuria M Hirsch1, Vivien Toth, Annette Förschler, Hendrik Kooijman, Claus Zimmer, Christine Preibisch.   

Abstract

A blood oxygenation level-dependent (BOLD)-based apparent relative oxygen extraction fraction (rOEF) as a semi-quantitative marker of vascular deoxygenation has recently been introduced in clinical studies of patients with glioma and stroke, yielding promising results. These rOEF measurements are based on independent quantification of the transverse relaxation times T2 and T2* and relative cerebral blood volume (rCBV). Simulations demonstrate that small errors in any of the underlying measures may result in a large deviation of the calculated rOEF. Therefore, we investigated the validity of such measurements. For this, we evaluated the quantitative measurements of T2 and T2* at 3 T in a gel phantom, in healthy subjects and in healthy tissue of patients with brain tumors. We calculated rOEF maps covering large portions of the brain from T2, T2* and rCBV [routinely measured in patients using dynamic susceptibility contrast (DSC)], and obtained rOEF values of 0.63 ± 0.16 and 0.90 ± 0.21 in healthy-appearing gray matter (GM) and white matter (WM), respectively; values of about 0.4 are usually reported. Quantitative T2 mapping using the fast, clinically feasible, multi-echo gradient spin echo (GRASE) approach yields significantly higher values than much slower multiple single spin echo (SE) experiments. Although T2* mapping is reliable in magnetically homogeneous tissues, uncorrectable macroscopic background gradients and other effects (e.g. iron deposition) shorten T2*. Cerebral blood volume (CBV) measurement using DSC and normalization to WM yields robust estimates of rCBV in healthy-appearing brain tissue; absolute quantification of the venous fraction of CBV, however, is difficult to achieve. Our study demonstrates that quantitative measurements of rOEF are currently biased by inherent difficulties in T2 and CBV quantification, but also by inadequacies of the underlying model. We argue, however, that standardized, reproducible measurements of apparent T2, T2* and rCBV may still allow the estimation of a meaningful apparent rOEF, which requires further validation in clinical studies.
Copyright © 2014 John Wiley & Sons, Ltd.

Entities:  

Keywords:  apparent relative oxygen extraction fraction (rOEF); cerebral blood volume (CBV); quantitative blood oxygenation level dependent (qBOLD); relaxometry; vascular deoxygenation

Mesh:

Substances:

Year:  2014        PMID: 24809665     DOI: 10.1002/nbm.3131

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  17 in total

1.  Simultaneous pH-sensitive and oxygen-sensitive MRI of human gliomas at 3 T using multi-echo amine proton chemical exchange saturation transfer spin-and-gradient echo echo-planar imaging (CEST-SAGE-EPI).

Authors:  Robert J Harris; Jingwen Yao; Ararat Chakhoyan; Catalina Raymond; Kevin Leu; Linda M Liau; Phioanh L Nghiemphu; Albert Lai; Noriko Salamon; Whitney B Pope; Timothy F Cloughesy; Benjamin M Ellingson
Journal:  Magn Reson Med       Date:  2018-04-06       Impact factor: 4.668

2.  Poster Viewing Sessions PA00-A01 to PA00-A49.

Authors: 
Journal:  J Cereb Blood Flow Metab       Date:  2019-07       Impact factor: 6.200

3.  Characterizing white matter fiber orientation effects on multi-parametric quantitative BOLD assessment of oxygen extraction fraction.

Authors:  Stephan Kaczmarz; Jens Göttler; Claus Zimmer; Fahmeed Hyder; Christine Preibisch
Journal:  J Cereb Blood Flow Metab       Date:  2019-04-05       Impact factor: 6.200

4.  Oxygen metabolism MRI - A comparison with perfusion imaging in a rat model of MCA branch occlusion and reperfusion.

Authors:  Philip V Little; Sandra E Kraft; Arvin Chireh; Peter Damberg; Staffan Holmin
Journal:  J Cereb Blood Flow Metab       Date:  2019-12-16       Impact factor: 6.200

5.  The relationship between blood flow impairment and oxygen depletion in acute ischemic stroke imaged with magnetic resonance imaging.

Authors:  Alexander Seiler; Nicholas P Blockley; Ralf Deichmann; Ulrike Nöth; Oliver C Singer; Michael A Chappell; Johannes C Klein; Marlies Wagner
Journal:  J Cereb Blood Flow Metab       Date:  2017-09-20       Impact factor: 6.200

6.  Metabolic characterization of human IDH mutant and wild type gliomas using simultaneous pH- and oxygen-sensitive molecular MRI.

Authors:  Jingwen Yao; Ararat Chakhoyan; David A Nathanson; William H Yong; Noriko Salamon; Catalina Raymond; Sergey Mareninov; Albert Lai; Phioanh L Nghiemphu; Robert M Prins; Whitney B Pope; Richard G Everson; Linda M Liau; Timothy F Cloughesy; Benjamin M Ellingson
Journal:  Neuro Oncol       Date:  2019-09-06       Impact factor: 12.300

7.  Mapping of cerebral metabolic rate of oxygen using dynamic susceptibility contrast and blood oxygen level dependent MR imaging in acute ischemic stroke.

Authors:  Alexandra S Gersing; Monika Ankenbrank; Benedikt J Schwaiger; Vivien Toth; Insa Janssen; Hendrik Kooijman; Silke Wunderlich; Jan S Bauer; Claus Zimmer; Christine Preibisch
Journal:  Neuroradiology       Date:  2015-09-12       Impact factor: 2.804

8.  Flow-metabolism uncoupling in patients with asymptomatic unilateral carotid artery stenosis assessed by multi-modal magnetic resonance imaging.

Authors:  Jens Göttler; Stephan Kaczmarz; Michael Kallmayer; Isabel Wustrow; Hans-Henning Eckstein; Claus Zimmer; Christian Sorg; Christine Preibisch; Fahmeed Hyder
Journal:  J Cereb Blood Flow Metab       Date:  2018-07-03       Impact factor: 6.200

9.  Predicting brain tumor regrowth in relation to motor areas by functional brain mapping.

Authors:  Nico Sollmann; Tobias Laub; Anna Kelm; Lucia Albers; Jan S Kirschke; Stephanie E Combs; Bernhard Meyer; Sandro M Krieg
Journal:  Neurooncol Pract       Date:  2017-09-06

10.  Role of 3T multiparametric-MRI with BOLD hypoxia imaging for diagnosis and post therapy response evaluation of postoperative recurrent cervical cancers.

Authors:  Abhishek Mahajan; Reena Engineer; Supriya Chopra; Umesh Mahanshetty; S L Juvekar; S K Shrivastava; Naresh Desekar; M H Thakur
Journal:  Eur J Radiol Open       Date:  2015-12-12
View more