Literature DB >> 24809320

Optimizing image contrast display improves quantitative stenosis measurement in heavily calcified coronary arterial segments on coronary CT angiography: A proof-of-concept and comparison to quantitative invasive coronary angiography.

Haim Shmilovich1, Victor Y Cheng2, Damini Dey2, Ronak Rajani2, Ryo Nakazato2, Yuka Otaki2, Rine Nakanishi2, Vishal Vashistha3, James K Min2, Daniel S Berman2.   

Abstract

RATIONALE AND
OBJECTIVES: Blooming artifact from calcified plaques often renders measurement of stenosis impossible on coronary computed tomographic angiography (CTA). We sought to evaluate the impact of modifying window level on reducing blooming artifact, and its impact on stenosis quantification.
MATERIALS AND METHODS: We analyzed 125 calcified segments from 53 patients who underwent CTA and invasive coronary angiography (ICA). Segmental stenosis on CTA was measured using three window settings: width of 1000 Hounsfield units (HU) and level of 200 HU ("default"), 1500/200 HU ("widened"), and width and level based on the mean HU of the calcified plaque and pericoronary fat ("calcium-specific"). Segmental stenosis on ICA was quantified by a blinded experienced reader.
RESULTS: ICA found ≥50% stenosis in 30 segments. Displaying segments with widened and calcium-specific settings improved overall accuracy of detecting ≥50% stenosis (P's < 0.001) by increasing the rate of accurately quantifying <50% stenosis (P's < 0.001), and improved correlation of stenosis quantification to ICA (P's < 0.05). There was no difference in stenosis quantification accuracy between widened and calcium-specific window settings. Limits of agreement between CTA stenosis quantification and ICA narrowed with widened and calcium-specific settings.
CONCLUSIONS: We showed for the first time that in calcified segments, widening display window width significantly improved CTA quantification of stenosis compared to ICA.
Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Image contrast display; blooming artifact; calcified plaque; coronary CT angiography; stenosis measurement

Mesh:

Substances:

Year:  2014        PMID: 24809320     DOI: 10.1016/j.acra.2014.02.016

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  5 in total

Review 1.  The challenge of coronary calcium on coronary computed tomographic angiography (CCTA) scans: effect on interpretation and possible solutions.

Authors:  Makmur Andrew; Hoe John
Journal:  Int J Cardiovasc Imaging       Date:  2015-09-25       Impact factor: 2.357

2.  Incremental improvement of diagnostic performance of coronary CT angiography for the assessment of coronary stenosis in the presence of calcium using a dual-layer spectral detector CT: validation by invasive coronary angiography.

Authors:  Cheng Xu; Yan Yi; Yechen Han; Hongzhi Xie; Xiaomei Lu; Mani Vembar; Tim Leiner; Zhengyu Jin; Yining Wang
Journal:  Int J Cardiovasc Imaging       Date:  2021-06-27       Impact factor: 2.357

3.  Instantaneous wave-free ratio derived from coronary computed tomography angiography in evaluation of ischemia-causing coronary stenosis: Feasibility and initial clinical research.

Authors:  Yue Ma; Hui Liu; Yang Hou; Aike Qiao; Yingying Hou; Qingqing Yang; Qiyong Guo
Journal:  Medicine (Baltimore)       Date:  2017-01       Impact factor: 1.889

4.  Algorithm of Pulmonary Vascular Segment and Centerline Extraction.

Authors:  Shi Qiu; Jie Lian; Yan Ding; Tao Zhou; Ting Liang
Journal:  Comput Math Methods Med       Date:  2021-08-25       Impact factor: 2.238

5.  Imaging Artifacts of Nonadhesive Liquid Embolic Agents in Conventional and Cone-beam CT in a Novel in Vitro AVM Model.

Authors:  Niclas Schmitt; Ralf O Floca; Daniel Paech; Rami A El Shafie; Ulf Neuberger; Martin Bendszus; Markus A Möhlenbruch; Dominik F Vollherbst
Journal:  Clin Neuroradiol       Date:  2021-04-14       Impact factor: 3.649

  5 in total