Literature DB >> 24809309

Comparison of endothelial cell density of organ cultured corneas with cornea donor study.

Nelly Campolmi1, Zhiguo He, Sophie Acquart, Marie-Caroline Trone, Aurélien Bernard, Anne-Sophie Gauthier, Olivier Garraud, Fabien Forest, Michel Péocʼh, Philippe Gain, Gilles Thuret.   

Abstract

PURPOSE: Determination of the endothelial cell density (ECD) by eye banks is paramount in donor cornea qualification. Unbiased measurement avoids wastage and grafts with an increased risk of premature failure. Internal calibration of the counting method is essential, but external validation would add an extra stage in the assessment of reliability. In this respect, data published by the multicenter Cornea Donor Study (CDS) in 2005 is a reference. The aim of the study was to compare ECD determined within a single eye bank, which uses calibrated image analysis software designed for transmitted light microscopy images of organ cultured corneas, with the CDS data determined on specular microscopy images of corneas stored at 4°C.
METHODS: ECD of consecutive corneas retrieved between 2005 and 2013 was determined after exposure to 0.9% NaCl. More than 300 ECs were counted on 3 fields of the central 8 mm. Endothelial cell boundaries were automatically drawn and verified by a skilled technician who performed all necessary corrections.
RESULTS: Three thousand fifty-two corneas were analyzed, of which 48.5% donors were >75 years (CDS upper age limit). Between 10 and 75 years, the ECD varied according to donor age exactly in the same manner as in the CDS, but were consistently higher of 100 ± 25 cells per square millimeter (P < 0.001).
CONCLUSIONS: ECD determined by a computer-aided method from transmitted light microscopy images compares favorably with the American CDS reference series. The slight systematic difference on either side of the Atlantic Ocean could be due to (1) differences in counting principles and/or (2) higher shrinkage of the cornea caused by stromal edema in organ culture.

Entities:  

Mesh:

Year:  2014        PMID: 24809309     DOI: 10.1097/ICO.0000000000000124

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  2 in total

1.  Factors that influence the suitability of human organ-cultured corneas.

Authors:  T Röck; J Hofmann; S Thaler; M Bramkamp; K U Bartz-Schmidt; E Yoeruek; D Röck
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-08-20       Impact factor: 3.117

2.  Delivery of Molecules into Human Corneal Endothelial Cells by Carbon Nanoparticles Activated by Femtosecond Laser.

Authors:  Clotilde Jumelle; Cyril Mauclair; Julien Houzet; Aurélien Bernard; Zhiguo He; Fabien Forest; Michel Peoc'h; Sophie Acquart; Philippe Gain; Gilles Thuret
Journal:  PLoS One       Date:  2015-07-02       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.