| Literature DB >> 24804118 |
Sachin Narain1, Gian Paparcuri1, Thomas M Fuhrman1, Richard B Silverman1, William T Peruzzi1.
Abstract
A 31-year-old male was transferred to our hospital with severe heart failure due to viral myocarditis. He progressed to multiorgan failure requiring intubation and maximal doses of multiple vasopressors. Circulatory support was provided with an Impella device as a bridge to an extracorporeal membrane oxygenation (ECMO) system. On full mechanical cardiovascular support, the patient's hemodynamic status improved and ECMO and Impella were explanted after 48 hours. Three days later, he was extubated and continued on to a full recovery. There are no specific therapies for fulminant myocarditis but first-line treatment is supportive care. ECMO is commonly used in patients with severe heart failure. In severe systolic dysfunction, left ventricular decompression is required to reduce myocardial wall stress, decrease myocardial oxygen requirements, and enhance the chances of recovery. The Impella, an active support system, is less invasive than classical decompressive techniques and is associated with lower requirements for blood products with fewer thromboembolic complications. This is the only case reported of the contemporary use of Impella and ECMO as a bridge to full recovery in an adult with myocarditis. It also presents a novel use of the Impella device in decompressing the left ventricle of an adult patient on ECMO.Entities:
Year: 2012 PMID: 24804118 PMCID: PMC4010068 DOI: 10.1155/2012/459296
Source DB: PubMed Journal: Case Rep Crit Care ISSN: 2090-6420
Changes in hemodynamic parameters following Impella implantation.
| Index | Pre-Impella | Post-Impella |
|---|---|---|
| MAP (mmHg) | 47 | 66 |
| CVP (mmHg) | 14 | 22 |
| CI (L/min/m2) | 2.9 | 4.0 |
| SVR (dyn-s-cm−5) | 600 | 300 |
All hemodynamic parameters improved in the initial post-implantation period. For the pre-Impella values, the patient was still on multiple vasopressor agents. For the post-Impella values, vasopressors had been nearly titrated off. (MAP: mean arterial pressure, CVP: central venous pressure, CI: cardiac index, SVR: systemic vascular resistance).