Literature DB >> 24802953

Electrochemical activation of diamond microelectrodes: implications for the in vitro measurement of serotonin in the bowel.

Boris Duran1, Ricardo F Brocenschi, Marion France, James J Galligan, Greg M Swain.   

Abstract

The electrochemical pretreatment of diamond microelectrodes was investigated for the purpose of learning how an anodic, cathodic or a combined anodic + cathodic polarization affects the charge-transfer kinetics for two surface-sensitive redox systems: ferri/ferrocyanide and serotonin (5-hydroxytryptamine, 5-HT). The pretreatments were performed in 0.5 mol L(-1) H2SO4. The anodic pretreatment was performed galvanically for 30 s at 250 mA cm(-2). The cathodic pretreatment was performed for 180 s at -250 mA cm(-2). The combined pretreatment involved application of the anodic step first followed by the cathodic step. The results clearly demonstrate that the best performance for both redox systems is obtained after the cathodic polarization, which presumably activates the electrode by cleaning the surface and removing site-blocking surface carbon-oxygen functionalities. The cathodic pretreatment was found to be effective at activating a fouled microelectrode in situ. This observation has important implication for the measurement of 5-HT in the bowel.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24802953      PMCID: PMC4266237          DOI: 10.1039/c4an00506f

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  10 in total

1.  Electrochemical performance of diamond thin-film electrodes from different commercial sources.

Authors:  Anne E Fischer; Yoshiyuki Show; Greg M Swain
Journal:  Anal Chem       Date:  2004-05-01       Impact factor: 6.986

2.  Understanding changes in uptake and release of serotonin from gastrointestinal tissue using a novel electroanalytical approach.

Authors:  Gianluca Marcelli; Bhavik Anil Patel
Journal:  Analyst       Date:  2010-07-02       Impact factor: 4.616

3.  The analysis of estrogenic compounds by flow injection analysis with amperometric detection using a boron-doped diamond electrode.

Authors:  Ricardo F Brocenschi; Romeu C Rocha-Filho; Boris Duran; Greg M Swain
Journal:  Talanta       Date:  2014-03-24       Impact factor: 6.057

4.  Improvements in the Formation of Boron-Doped Diamond Coatings on Platinum Wires Using the Novel Nucleation Process (NNP).

Authors:  Mathew Fhaner; Hong Zhao; Xiaochun Bian; James J Galligan; Greg M Swain
Journal:  Diam Relat Mater       Date:  2011-02       Impact factor: 3.315

5.  In vitro continuous amperometric monitoring of 5-hydroxytryptamine release from enterochromaffin cells of the guinea pig ileum.

Authors:  Bhavik Anil Patel; Xiaochun Bian; Veronika Quaiserová-Mocko; James J Galligan; Greg M Swain
Journal:  Analyst       Date:  2006-11-09       Impact factor: 4.616

6.  Electrochemical measurements of serotonin (5-HT) release from the guinea pig mucosa using continuous amperometry with a boron-doped diamond microelectrode.

Authors:  Hong Zhao; Xiaochun Bian; James J Galligan; Greg M Swain
Journal:  Diam Relat Mater       Date:  2010-02       Impact factor: 3.315

7.  In vitro continuous amperometry with a diamond microelectrode coupled with video microscopy for simultaneously monitoring endogenous norepinephrine and its effect on the contractile response of a rat mesenteric artery.

Authors:  Jinwoo Park; James J Galligan; Gregory D Fink; Greg M Swain
Journal:  Anal Chem       Date:  2006-10-01       Impact factor: 6.986

8.  Boron-doped diamond microelectrodes for use in capillary electrophoresis with electrochemical detection.

Authors:  Josef Cvacka; Veronika Quaiserová; JinWoo Park; Yoshiyuki Show; Alexander Muck; Greg M Swain
Journal:  Anal Chem       Date:  2003-06-01       Impact factor: 6.986

9.  Further insights into the oxidation chemistry of 5-hydroxytryptamine.

Authors:  M Z Wrona; G Dryhurst
Journal:  J Pharm Sci       Date:  1988-11       Impact factor: 3.534

Review 10.  Serotonin release and uptake in the gastrointestinal tract.

Authors:  Paul P Bertrand; Rebecca L Bertrand
Journal:  Auton Neurosci       Date:  2009-09-02       Impact factor: 3.145

  10 in total
  3 in total

1.  Electrochemical detection of peroxynitrite using hemin-PEDOT functionalized boron-doped diamond microelectrode.

Authors:  Serban F Peteu; Brandon W Whitman; James J Galligan; Greg M Swain
Journal:  Analyst       Date:  2016-03-07       Impact factor: 4.616

2.  Analytical Techniques in Neuroscience: Recent Advances in Imaging, Separation, and Electrochemical Methods.

Authors:  Mallikarjunarao Ganesana; Scott T Lee; Ying Wang; B Jill Venton
Journal:  Anal Chem       Date:  2016-11-22       Impact factor: 6.986

3.  Continuous and selective measurement of oxytocin and vasopressin using boron-doped diamond electrodes.

Authors:  Kai Asai; Tribidasari A Ivandini; Yasuaki Einaga
Journal:  Sci Rep       Date:  2016-09-07       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.