Randomised study of a bioabsorbable polymer-coated sirolimus-eluting stent: results of the DESSOLVE II trial.

William Wijns1, Mathias Vrolix, Stefan Verheye, Danny Schoors, Ton Slagboom, Marcel Gosselink, Edouard Benit, Dennis Donohoe, Charlene Knape, Guilherme F Attizzani, Alexandra J Lansky, John Ormiston.   

Abstract

AIMS: To compare the efficacy and safety of the MiStent absorbable polymer sirolimus-eluting stent (APSES) with a zotarolimus-eluting stent (ZES). METHODS AND
RESULTS: The trial was a 2:1 randomisation at 26 sites of 184 patients implanted with an APSES (n=123) versus a ZES (n=61). Following stent implantation, all patients underwent quantitative coronary angiography at baseline and at nine months of follow-up, while a select subgroup also underwent optical coherence tomography (OCT). The primary efficacy hypothesis was superiority of in-stent late lumen loss (LLL) of APSES compared to ZES. At nine months, the primary endpoint was met, with a mean in-stent LLL of 0.27±0.46 mm in 103 APSES patients versus 0.58±0.41 mm in 52 ZES patients (p<0.001). The proportion of uncovered stent struts by OCT at nine months was very low in both groups. The mean neointimal thickness of covered struts (p=0.002) and percent net volume obstruction (p≤0.003) were significantly lower in the APSES than in the ZES group. Major adverse cardiac event and stent thrombosis rates were low and comparable between groups.
CONCLUSIONS: The DESSOLVE II trial demonstrated superiority in the primary efficacy endpoint of nine-month mean LLL for APSES compared to ZES. Strut coverage by OCT was high with both stents and the clinical safety endpoints including stent thrombosis were equally low in both groups. ClinicalTrials.gov Identifier: NCT01294748.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 24801119     DOI: 10.4244/EIJY14M05_03

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  5 in total

Review 1.  Thrombotic responses to coronary stents, bioresorbable scaffolds and the Kounis hypersensitivity-associated acute thrombotic syndrome.

Authors:  Nicholas G Kounis; Ioanna Koniari; Anastasios Roumeliotis; Grigorios Tsigkas; George Soufras; Nicholas Grapsas; Periklis Davlouros; George Hahalis
Journal:  J Thorac Dis       Date:  2017-04       Impact factor: 2.895

2.  Comparison of the Absorbable Polymer Sirolimus-Eluting Stent (MiStent) to the Durable Polymer Everolimus-Eluting Stent (Xience) (from the DESSOLVE I/II and ISAR-TEST-4 Studies).

Authors:  Alexandra J Lansky; Adnan Kastrati; Elazer R Edelman; Helen Parise; Vivian G Ng; John Ormiston; William Wijns; Robert A Byrne
Journal:  Am J Cardiol       Date:  2015-12-07       Impact factor: 2.778

3.  Long-term follow-up after ultrathin vs. conventional 2nd-generation drug-eluting stents: a systematic review and meta-analysis of randomized controlled trials.

Authors:  Mahesh V Madhavan; James P Howard; Azim Naqvi; Ori Ben-Yehuda; Bjorn Redfors; Megha Prasad; Bahira Shahim; Martin B Leon; Sripal Bangalore; Gregg W Stone; Yousif Ahmad
Journal:  Eur Heart J       Date:  2021-07-15       Impact factor: 29.983

4.  Current State of Bioabsorbable Polymer-Coated Drug-Eluting Stents.

Authors:  Abhilash Akinapelli; Jack P Chen; Kristine Roy; Joseph Donnelly; Keith Dawkins; Barbara Huibregtse; Dongming Hou
Journal:  Curr Cardiol Rev       Date:  2017

5.  Biodegradable polymer versus second-generation durable polymer drug-eluting stents in patients with coronary artery disease: A meta-analysis.

Authors:  James J Wu; Joshua A H Way; Probal Roy; Andy Yong; Harry Lowe; Leonard Kritharides; David Brieger
Journal:  Health Sci Rep       Date:  2018-10-05