Literature DB >> 24798390

Assessing the imaging capabilities of radial mechanical and electronic echo-endoscopes using the resolution integral.

Scott Inglis1, Anna Janeczko2, William Ellis2, John N Plevris3, Stephen D Pye2.   

Abstract

Over the past decade there have been significant advances in endoscopic ultrasound (EUS) technology. Although there is an expectation that new technology will deliver improved image quality, there are few methods or phantoms available for assessing the capabilities of mechanical and electronic EUS systems. The aim of this study was to investigate the possibility of assessing the imaging capability of available EUS technologies using measurements of the resolution integral made with an Edinburgh Pipe Phantom. Various radial EUS echo-endoscopes and probes were assessed using an Edinburgh Pipe Phantom. Measurements of the resolution integral (R), depth of field (LR) and characteristic resolution (DR) were made at all operating frequencies. The mean R value for Fuji miniprobes was 16.0. The GF-UM20 and GF-UM2000 mechanical radial scopes had mean R values of 24.0 and 28.5, respectively. The two electronic radial echo-endoscopes had similar mean R values of 34.3 and 34.6 for the Olympus GF-UE260 and Fujinon EG-530 UR scopes, respectively. Despite being older technology, the mechanical GF-UM2000 scope had superior characteristic resolution (DR), but could not compare with the depths of field (LR) delivered by the current generation of electronic radial scopes, especially at the standard operating frequencies of 7.5 and 12 MHz.
Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Keywords:  Edinburgh Pipe Phantom; Endoscopic ultrasound; Radial; Resolution integral

Mesh:

Year:  2014        PMID: 24798390     DOI: 10.1016/j.ultrasmedbio.2014.02.009

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  3 in total

1.  Quality assurance testing of transoesophageal echocardiography probes.

Authors:  Christopher McLeod; Kirsty McNeill; Karne McBride; Scott Inglis; Stephen D Pye
Journal:  Ultrasound       Date:  2016-08-23

2.  The Resolution Integral - a tool for characterising the performance of diagnostic ultrasound scanners.

Authors:  Carmel M Moran; Scott Inglis; Stephen D Pye
Journal:  Ultrasound       Date:  2014-02-06

3.  Evaluation of a novel radial echoendosonoscope with a piezoelectric-composite transducer: An open-label, multicenter, randomized, parallel-group, noninferiority clinical trial.

Authors:  Sheng Wang; Jintao Guo; Xiang Liu; Nan Ge; Guoxin Wang; Jinlong Hu; Kai Zhang; Siyu Sun
Journal:  Endosc Ultrasound       Date:  2021 Nov-Dec       Impact factor: 5.628

  3 in total