Literature DB >> 24796842

Foreign body granulomatous reaction associated with polyethelene 'Fiberwire(®)' suture material used in Achilles tendon repair.

Ben J Ollivere1, Hilary A Bosman2, Philip W P Bearcroft3, Andrew H N Robinson4.   

Abstract

Repair of acute Achilles tendon rupture is a common procedure. There are many accepted surgical techniques; suture selection is largely due to surgeon preference. We present a case report of a granulomatous reaction to suture material following Achilles tendon repair. 'Fiberwire(®)' is an increasingly popular suture material for the repair of tendons and ligamentous structures; the polyethelene braided structure with silicone and polyester coating provides high tensile strengths and good handling characteristics. Eight months following uneventful Achilles tendon repair surgery in an otherwise fit and well patient, pain, swelling and loss of function was noted. She required revision surgery with debridement and reconstruction of the tendo Achillis with flexor hallucis longus tendon transfer. Histology revealed a granulomatous reaction with giant cell response surrounding sections of the suture. Both the silicone coating of Fiberwire(®) and polyethylene core have the potential to cause a severe granulomatous reaction. We would advise caution in the use of this suture for tendo Achillis repair, and use the readily available alternatives.
Copyright © 2014 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Achilles; Fiberwire; Tendo Achillis; Tendon repair

Mesh:

Substances:

Year:  2014        PMID: 24796842     DOI: 10.1016/j.fas.2014.01.006

Source DB:  PubMed          Journal:  Foot Ankle Surg        ISSN: 1268-7731            Impact factor:   2.705


  10 in total

1.  Extensor Pollicis Longus Rupture after Mini TightRope Suspensionplasty.

Authors:  Mani Seetharaman; Mark A Vitale; Kapil Desai; John F Crowe
Journal:  J Wrist Surg       Date:  2016-01-06

2.  Intra-lingual suture pattern for prevention of self-suckling in cows.

Authors:  A M Seddek; M Abdelfattah; M H Elrashidy; F A Mahmoud; F A Zakaib
Journal:  Vet Anim Sci       Date:  2019-09-14

3.  A delayed foreign body granuloma associated with polypropylene sutures used in tendon transfer. A case report.

Authors:  Mohammad M Al-Qattan; Khalid Al-Zahrani; Hala Kfoury; Noha M Al-Qattan; Turki A Al-Thunayan
Journal:  Int J Surg Case Rep       Date:  2016-07-28

4.  Osteolysis of the Greater Trochanter Caused by a Foreign Body Granuloma Associated with the Ethibond® Suture after Total Hip Arthroplasty.

Authors:  Keiji Kamo; Hiroaki Kijima; Koichiro Okuyama; Nobutoshi Seki; Shin Yamada; Naohisa Miyakoshi; Yoichi Shimada
Journal:  Case Rep Orthop       Date:  2017-01-31

5.  Effects of Cyanoacrylate in Rabbits with Induced Achilles Tendon Rupture.

Authors:  Mehmet Murat Bala; Abdullah Alper Şahin; Mehmet Boz; Yasin Durukan; Tülin Fırat; Murat Pakdil; Kutay Engin Özturan
Journal:  Med Sci Monit       Date:  2021-09-06

6.  Clinical Features and Treatment of Intra-Tendinous Suture Reaction Following Achilles Tendon Repair Using Nonabsorbable Suture Material: A Retrospective Case Series Study.

Authors:  Jahyung Kim; Hwa-Jun Kang; Bom-Soo Kim; Yu-Mi Kim; Hyong-Nyun Kim; Jae-Yong Park; Young-Rak Choi; Altanzul Bat-Ulzii; Jaeho Cho
Journal:  Int J Environ Res Public Health       Date:  2022-10-08       Impact factor: 4.614

7.  Granuloma formation secondary to Achilles tendon repair with nonabsorbable suture.

Authors:  Adnan Kara; Haluk Celik; Ali Seker; Mehmet Ali Uysal; Metin Uzun; Melih Malkoc
Journal:  Int J Surg Case Rep       Date:  2014-08-07

8.  Four-Strand Core Suture Improves Flexor Tendon Repair Compared to Two-Strand Technique in a Rabbit Model.

Authors:  Alice Wichelhaus; Sascha Tobias Beyersdoerfer; Brigitte Vollmar; Thomas Mittlmeier; Philip Gierer
Journal:  Biomed Res Int       Date:  2016-06-30       Impact factor: 3.411

9.  An Exceptional Case of Suture Granuloma 30 Years Following an Open Repair of Achilles Tendon Rupture: A Case Report.

Authors:  Ömer Naci Ergin; Mehmet Demirel; Emre Özmen
Journal:  J Orthop Case Rep       Date:  2017 May-Jun

10.  Suture-Based Debris Behavior in the Draining Lymph Nodes of a Porcine Knee: A Study of Silicone, Polyethylene and Carbon.

Authors:  F Alan Barber; David B Spenciner; Brett G Zani; Raffaele Melidone
Journal:  Arthrosc Sports Med Rehabil       Date:  2019-11-27
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.