Prospective, randomized study of cutting balloon angioplasty versus conventional balloon angioplasty for the treatment of hemodialysis access stenoses.

Hossam M Saleh1, Ahmed K Gabr2, Mohamed M Tawfik2, Hesham Abouellail3.   

Abstract

OBJECTIVE: The aim of this trial was to compare the rates of patency achieved by cutting and conventional balloon angioplasty to treat hemodialysis access stenoses.
METHODS: End-stage renal failure patients (at three tertiary referral centers) with significant hemodialysis access stenoses were prospectively randomized to have percutaneous transluminal angioplasty (PTA) by either cutting or conventional balloons. Patients with more than one hemodynamically significant stenosis were excluded. Kaplan-Meier method was used to compare the primary assisted patency rates for the two groups.
RESULTS: The study randomized 623 patients into two groups, and the duration of follow-up was 15 ± 3 months. In the cutting balloon angioplasty group, the clinical success rate was 89% (282 of 316 stenoses). In the conventional balloon angioplasty group, the clinical success rate was 86% (265 of 307 stenoses; P = .637). Assisted primary patency for cutting PTA was statistically significantly higher at 6 months and 1 year (86% and 63%) than that for conventional PTA (56% and 37%, respectively; P = .037) in the treatment of stenosis of the graft-to-vein anastomosis. In the venous stenosis subgroup, equivalent primary assisted patency at 6 months and 1 year was observed for cutting PTA (84% and 55%) and conventional PTA (70% and 46%, respectively; P = .360). In the intragraft stenosis subgroup, primary assisted patency was equivalent at 6 months and 1 year for cutting PTA (67% and 39%) and conventional PTA (62% and 49%, respectively; P = .371). In the arterial anastomotic stenosis subgroup, assisted primary patency at 6 months and 1 year was equivalent for cutting PTA (70% and 30%) and conventional PTA (75% and 33%, respectively; P = .921).
CONCLUSIONS: Cutting balloon angioplasty proved to be a safe and effective treatment of graft-to-vein anastomotic stenosis, with significantly higher patency than that of conventional balloon angioplasty.
Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 24794277     DOI: 10.1016/j.jvs.2014.04.002

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  7 in total

1.  Outcomes of different treatments on Takayasu's arteritis.

Authors:  Yu Xiao; Jian Zhou; Xiaolong Wei; Yudong Sun; Lei Zhang; Jiaxuan Feng; Rui Feng; Zhiqing Zhao; Zaiping Jing
Journal:  J Thorac Dis       Date:  2016-09       Impact factor: 2.895

Review 2.  Important Contributions to the Interventional Radiology Dialysis Literature, 2014-2015.

Authors:  Charles E Ray; Brian Funaki; Ron C Gaba
Journal:  Semin Intervent Radiol       Date:  2016-03       Impact factor: 1.513

3.  Usefulness of paclitaxel-releasing high-pressure balloon associated with cutting balloon angioplasty for treatment of outflow stenoses of failing hemodialysis arteriovenous shunts.

Authors:  Anna Maria Ierardi; Marco Franchin; Federico Fontana; Gabriele Piffaretti; Ejona Duka; Massimo Tonolini; Vittorio Miele; Matteo Tozzi; Gianpaolo Carrafiello
Journal:  Radiol Med       Date:  2016-09-06       Impact factor: 3.469

4.  Monocyte Chemoattractant Protein-1 Levels and Postangioplasty Restenosis of Arteriovenous Fistulas.

Authors:  Chih-Cheng Wu; Tsung-Yan Chen; Mu-Yang Hsieh; Lin Lin; Chung-Wei Yang; Shao-Yuan Chuang; Der-Cheng Tarng
Journal:  Clin J Am Soc Nephrol       Date:  2016-10-26       Impact factor: 8.237

Review 5.  Dialysis Access Anatomy and Interventions: A Primer.

Authors:  Charles Martin; Rex Pillai
Journal:  Semin Intervent Radiol       Date:  2016-03       Impact factor: 1.513

6.  Predictors of primary patency after percutaneous balloon angioplasty for stenosis of Brescia-Cimino hemodialysis arteriovenous fistula.

Authors:  Zheng-Rong Zhu; Lan Zou; Yue Xing; Yu-Can Tan; Guo-Jian Xu; Zhi-Jian He; Jian-Qiang Cao; Jia-Yu Wu; Xiao-Xia Liang; Hui-Ping Zhang; Yan-Hong Tan; Can-Hua Luo
Journal:  Br J Radiol       Date:  2020-03-04       Impact factor: 3.039

7.  Drug-eluting balloon (DEB) versus plain old balloon angioplasty (POBA) in the treatment of failing dialysis access: A prospective randomized trial.

Authors:  Torbjörn Fransson; Anders Gottsäter; Mohammad Abdulrasak; Martin Malina; Timothy Resch
Journal:  J Int Med Res       Date:  2022-03       Impact factor: 1.671

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.