In-line monitoring of pellet coating thickness growth by means of visual imaging.

Nika Oman Kadunc1, Rok Sibanc2, Rok Dreu2, Boštjan Likar3, Dejan Tomaževič3.   

Abstract

Coating thickness is the most important attribute of coated pharmaceutical pellets as it directly affects release profiles and stability of the drug. Quality control of the coating process of pharmaceutical pellets is thus of utmost importance for assuring the desired end product characteristics. A visual imaging technique is presented and examined as a process analytic technology (PAT) tool for noninvasive continuous in-line and real time monitoring of coating thickness of pharmaceutical pellets during the coating process. Images of pellets were acquired during the coating process through an observation window of a Wurster coating apparatus. Image analysis methods were developed for fast and accurate determination of pellets' coating thickness during a coating process. The accuracy of the results for pellet coating thickness growth obtained in real time was evaluated through comparison with an off-line reference method and a good agreement was found. Information about the inter-pellet coating uniformity was gained from further statistical analysis of the measured pellet size distributions. Accuracy and performance analysis of the proposed method showed that visual imaging is feasible as a PAT tool for in-line and real time monitoring of the coating process of pharmaceutical pellets.
Copyright © 2014 Elsevier B.V. All rights reserved.

Keywords:  Coating thickness; Fluid-bed coating; PAT; Pellets; Quality assurance; Visual imaging

Mesh:

Substances:

Year:  2014        PMID: 24792980     DOI: 10.1016/j.ijpharm.2014.04.066

Source DB:  PubMed          Journal:  Int J Pharm        ISSN: 0378-5173            Impact factor:   5.875


  3 in total

1.  Impact of Processing Conditions on Inter-tablet Coating Thickness Variations Measured by Terahertz In-Line Sensing.

Authors:  Hungyen Lin; Robert K May; Michael J Evans; Shuncong Zhong; Lynn F Gladden; Yaochun Shen; J Axel Zeitler
Journal:  J Pharm Sci       Date:  2015-06-02       Impact factor: 3.534

2.  Assessment of Mini-Tablets Coating Uniformity as a Function of Fluid Bed Coater Inlet Conditions.

Authors:  Magdalena Turk; Rok Šibanc; Rok Dreu; Maja Frankiewicz; Małgorzata Sznitowska
Journal:  Pharmaceutics       Date:  2021-05-18       Impact factor: 6.321

Review 3.  Image Analysis: A Versatile Tool in the Manufacturing and Quality Control of Pharmaceutical Dosage Forms.

Authors:  Dóra Farkas; Lajos Madarász; Zsombor K Nagy; István Antal; Nikolett Kállai-Szabó
Journal:  Pharmaceutics       Date:  2021-05-10       Impact factor: 6.321

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.