Literature DB >> 24792493

Gait variability and stability measures: minimum number of strides and within-session reliability.

F Riva1, M C Bisi2, R Stagni3.   

Abstract

BACKGROUND: Several methods are proposed in the literature for the quantification of gait variability/stability from trunk accelerations. Since outputs can be influenced by implementation differences, reliability assessment and standardization of implementation parameters are still an issue. The aim of this study is to assess the minimum number of required strides and the within-session reliability of 11 variability/stability measures.
METHOD: Ten healthy participants walked in a straight line at self-selected speed wearing two synchronized tri-axial Inertial Measurement Units. Five variability measures were calculated based on stride times namely Standard deviation, Coefficient of variation, Inconsistency of variance, Nonstationary index and Poincaré plot. Six stability measures were calculated based on trunk accelerations namely Maximum Floquet multipliers, Short term/long term Lyapunov exponents, Recurrence quantification analysis, Multiscale entropy, Harmonic ratio and Index of harmonicity. The required minimum number of strides and the within-session reliability for each measure were obtained based on the interquartile range/mean ratio. Measures were classified in five categories (namely excellent, good, average, poor, and very poor) based on their reliability.
RESULTS: The number of strides required to obtain a reliable measure was generally larger than those conventionally used. Variability measures showed average to poor reliability, while stability measures ranged from excellent to very poor reliability.
CONCLUSION: Recurrence quantification analysis and multiscale entropy of trunk accelerations showed excellent reliability and a reasonable number of required strides. Based on these results, these measures should be taken into consideration in the assessment of fall risk.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Gait stability; Gait variability; Inertial sensors; Stride number; Within-session reliability

Mesh:

Year:  2014        PMID: 24792493     DOI: 10.1016/j.compbiomed.2014.04.001

Source DB:  PubMed          Journal:  Comput Biol Med        ISSN: 0010-4825            Impact factor:   4.589


  30 in total

1.  Understanding the effects of pre-processing on extracted signal features from gait accelerometry signals.

Authors:  Alexandre Millecamps; Kristin A Lowry; Jennifer S Brach; Subashan Perera; Mark S Redfern; Ervin Sejdić
Journal:  Comput Biol Med       Date:  2015-04-04       Impact factor: 4.589

2.  A Haptic Feedback System for Phase-Based Sensory Restoration in Above-Knee Prosthetic Leg Users.

Authors:  Aaron Plauche; Dario Villarreal; Robert D Gregg
Journal:  IEEE Trans Haptics       Date:  2016-06-14       Impact factor: 2.487

3.  The required number of trials for biomechanical analysis of a golf swing.

Authors:  Anna C Severin; Sally G Barnes; Stewart A Tackett; C Lowry Barnes; Erin M Mannen
Journal:  Sports Biomech       Date:  2019-01-30       Impact factor: 2.832

4.  Measures of gait stability: performance on adults and toddlers at the beginning of independent walking.

Authors:  Maria Cristina Bisi; Federico Riva; Rita Stagni
Journal:  J Neuroeng Rehabil       Date:  2014-09-03       Impact factor: 4.262

5.  A novel HMM distributed classifier for the detection of gait phases by means of a wearable inertial sensor network.

Authors:  Juri Taborri; Stefano Rossi; Eduardo Palermo; Fabrizio Patanè; Paolo Cappa
Journal:  Sensors (Basel)       Date:  2014-09-02       Impact factor: 3.576

6.  Concurrent transcranial direct current stimulation and progressive resistance training in Parkinson's disease: study protocol for a randomised controlled trial.

Authors:  Ashlee M Hendy; Alex Tillman; Timo Rantalainen; Makii Muthalib; Liam Johnson; Dawson J Kidgell; Daniel Wundersitz; Peter G Enticott; Wei-Peng Teo
Journal:  Trials       Date:  2016-07-19       Impact factor: 2.279

Review 7.  Entropy Analysis in Gait Research: Methodological Considerations and Recommendations.

Authors:  Jennifer M Yentes; Peter C Raffalt
Journal:  Ann Biomed Eng       Date:  2021-02-09       Impact factor: 3.934

8.  Ability of a Set of Trunk Inertial Indexes of Gait to Identify Gait Instability and Recurrent Fallers in Parkinson's Disease.

Authors:  Stefano Filippo Castiglia; Antonella Tatarelli; Dante Trabassi; Roberto De Icco; Valentina Grillo; Alberto Ranavolo; Tiwana Varrecchia; Fabrizio Magnifica; Davide Di Lenola; Gianluca Coppola; Donatella Ferrari; Alessandro Denaro; Cristina Tassorelli; Mariano Serrao
Journal:  Sensors (Basel)       Date:  2021-05-15       Impact factor: 3.576

9.  Are gait variability and stability measures influenced by directional changes?

Authors:  Federico Riva; Eleni Grimpampi; Claudia Mazzà; Rita Stagni
Journal:  Biomed Eng Online       Date:  2014-05-05       Impact factor: 2.819

10.  Intra-subject sample size effects in plantar pressure analyses.

Authors:  Juliet McClymont; Russell Savage; Todd C Pataky; Robin Crompton; James Charles; Karl T Bates
Journal:  PeerJ       Date:  2021-06-24       Impact factor: 2.984

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.