Literature DB >> 24792071

Varization open-wedge osteotomy of the distal femur: comparison between locking plate and angle blade plate constructs.

Bruno Bellaguarda Batista1, Jose Batista Volpon1, Antonio Carlos Shimano1, Mauricio Kfuri2,3.   

Abstract

PURPOSE: Biomechanical properties of locking plate and angle blade plate constructs in opening-wedge distal femur osteotomy were compared, with special attention to the impact of opposite cortex breakage and buttressing.
METHODS: Forty-eight synthetic femora underwent a lateral opening-wedge distal femur osteotomy, which was fixed either with a locking plate or with an angle blade plate. Two main groups were constituted based on the integrity of the opposite medial cortex-intact medial cortex and fractured medial cortex (FMC). Axial compression and torsion tests were performed comparing stiffness of all bone-implant constructs. In the group FMC, a special subgroup has been tested taking into consideration the effect of placing an additional 6.5-mm cancellous screw buttressing the medial cortex. Statistical level of significance was fixed in 0.05 using a confidence interval of 95 %.
RESULTS: Intact medial cortex significantly increased the stiffness for both implants tested in this study. In the FMC group, angle blade plate constructs reached higher stiffness mean values for both torsion and axial compression. The insertion of a buttressing screw on the medial cortex increased the stiffness of all tested bone-plate constructs. This additional screw favoured mostly locking plate constructs implementing their stiffness to torsion to mean values comparable to those reached by angle blade plate constructs.
CONCLUSIONS: Angle blade plate constructs reached higher stiffness mean values than locking plates for both axial compression and torsion loads. The addition of a buttressing screw on the opposite cortex increased the stability of all bone-implant constructs to levels similar to those showed with an intact medial cortex. The present study findings support the clinical use of angle blade plates, alone or associated with a medial buttressing screw, as an alternative fixation method for supracondylar open-wedge osteotomies of the femur.

Mesh:

Year:  2014        PMID: 24792071     DOI: 10.1007/s00167-014-2998-1

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  21 in total

1.  Open-wedge high tibial osteotomy: a technical trick to avoid loss of reduction of the opposite cortex.

Authors:  C A J Paccola; F Fogagnolo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-03-16       Impact factor: 4.342

Review 2.  [Open wedge osteotomy of the distal femur in the valgus knee].

Authors:  V Franco; M Cipolla; G Gerullo; E Gianni; G Puddu
Journal:  Orthopade       Date:  2004-02       Impact factor: 1.087

Review 3.  Osteotomies: the surgical treatment of the valgus knee.

Authors:  Giancarlo Puddu; Massimo Cipolla; Guglielmo Cerullo; Vittorio Franco; Enrico Giannì
Journal:  Sports Med Arthrosc Rev       Date:  2007-03       Impact factor: 1.985

4.  Distal femoral varus osteotomy for valgus deformity of the knee.

Authors:  A G McDermott; J A Finklestein; I Farine; E L Boynton; D L MacIntosh; A Gross
Journal:  J Bone Joint Surg Am       Date:  1988-01       Impact factor: 5.284

5.  Distal femoral varus osteotomy.

Authors:  W L Healy; J O Anglen; S A Wasilewski; K A Krackow
Journal:  J Bone Joint Surg Am       Date:  1988-01       Impact factor: 5.284

6.  Osteotomy about the knee for degenerative and rheumatoid arthritis.

Authors:  M B Coventry
Journal:  J Bone Joint Surg Am       Date:  1973-01       Impact factor: 5.284

7.  Comparison of the 95-degree angled blade plate and the locking condylar plate for the treatment of distal femoral fractures.

Authors:  Heather A Vallier; Wes Immler
Journal:  J Orthop Trauma       Date:  2012-06       Impact factor: 2.512

8.  Distal femoral varus osteotomy outcome: Is associated femoropatellar osteoarthritis consequential?

Authors:  A Zarrouk; R Bouzidi; B Karray; S Kammoun; S Mourali; M Kooli
Journal:  Orthop Traumatol Surg Res       Date:  2010-09-15       Impact factor: 2.256

9.  Distal femoral osteotomy for valgus arthritic knees.

Authors:  Rafael Thein; Shlomo Bronak; Ran Thein; Barak Haviv
Journal:  J Orthop Sci       Date:  2012-08-07       Impact factor: 1.601

10.  Which osteotomy for a valgus knee?

Authors:  Giancarlo Puddu; Massimo Cipolla; Guglielmo Cerullo; Vittorio Franco; Enrico Giannì
Journal:  Int Orthop       Date:  2009-06-23       Impact factor: 3.075

View more
  5 in total

1.  Supracondylar Osteotomy in Valgus Knee: Angle Blade Plate Versus Locking Compression Plate.

Authors:  Seyyed Morteza Kazemi; Reza Minaei; Farshad Safdari; Ali Keipourfard; Rozhin Forghani; Alemeh Mirzapourshafiei
Journal:  Arch Bone Jt Surg       Date:  2016-01

2.  Smoking and obesity influence the risk of nonunion in lateral opening wedge, closing wedge and torsional distal femoral osteotomies.

Authors:  Franz Liska; Bernhard Haller; Andreas Voss; Julian Mehl; Florian B Imhoff; Lukas Willinger; Andreas B Imhoff
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-11-08       Impact factor: 4.342

3.  A hinge position distal to the adductor tubercle minimizes the risk of hinge fractures in lateral open wedge distal femoral osteotomy.

Authors:  Philipp W Winkler; Marco C Rupp; Patricia M Lutz; Stephanie Geyer; Philipp Forkel; Andreas B Imhoff; Matthias J Feucht
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-08-24       Impact factor: 4.342

Review 4.  Experimental testing of fracture fixation plates: A review.

Authors:  Shiling Zhang; Dharmesh Patel; Mark Brady; Sherri Gambill; Kanthan Theivendran; Subodh Deshmukh; John Swadener; Sarah Junaid; Laura Jane Leslie
Journal:  Proc Inst Mech Eng H       Date:  2022-08-03       Impact factor: 1.763

5.  Dislocated hinge fractures are associated with malunion after lateral closing wedge distal femoral osteotomy.

Authors:  Marco-Christopher Rupp; Philipp W Winkler; Patricia M Lutz; Markus Irger; Philipp Forkel; Andreas B Imhoff; Matthias J Feucht
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-02-27       Impact factor: 4.342

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.