Iulia Badea1, Attila Tamas-Szora2, Ioana Chiorean3, Floarea Fildan4, Elisabeta Ciulea5, Mîndra Badea6. 1. Department of Conservative Odontology "Iuliu Haţieganu" University of Medicine and Pharmacy, Cluj Napoca, Romania. tamas-szora.attila@umfcluj.ro. 2. Imaging Department, "O. Fodor" Institute of Gastroenterology and Hepatology, "Iuliu Haţieganu" University of Medicine and Pharmacy, Cluj Napoca, Romania. 3. Faculty of Mathematics and Informatics, Department of Mathematics, Babes-Bolyai University Cluj Napoca Romania. 4. 4Departemnt of Maxilo-Facial Radiology "Iuliu Haţieganu" University of Medicine and Pharmacy, Cluj Napoca, Romania. 5. Department of Radiotherapy Oncologic Institute ''Prof.dr. Ion Chiricuta''Cluj Napoca, Romania. 6. Department of Preventive Dentistry, "Iuliu Haţieganu" University of Medicine and Pharmacy, Cluj Napoca, Romania.
Abstract
AIMS: The study proposes Acoustic Radiation Force Impulse (ARFI) assessment of the masseter muscle elasticity in the healthy population and in patients who have undergone head and neck radiation therapy. PATIENTS AND METHODS: Twenty-five healthy controls constituted group A, and 13 patients who had underwent radiotherapy (35Gy minimum) formed group B. ARFI was performed bilaterally in the periphery (P) and the muscle center (C), in relaxation and contraction. Means and standard deviations were obtained for the recorded shear waves velocities (SWV). RESULTS: For group A: in the relaxed right muscle C = 1.87±0.52 m/s and P = 1.96 ±0.55 m/s and in the left muscle C = 1.66 +/- 0.47 m/s, P = 1.67 +/-0.53 m/s. For group B, in relaxation, the right side presented C = 1.67 +/-0.6 m/s, P 1.72 +/-0.56 m/s, the left muscle C = 1.6 +/-0.34 m/s, P = 1.73 +/-0.37 m/s. There were no differences (p> 0.05) between P and C of both groups, regardless of the muscle state. The values for relaxation and contraction in A and B (merged values of the right and left) presented no differences (1.79+/-0.52 m/s vs 1.72 +/-0.73 m/s, p = 0.72 and 1.70 +/-0.48 m/s and vs 1.59 +/-0.77 m/s, p = 0.98). All measurements of group A vs B were not different (1.79 +/-0.52 m/s vs 1.65 +/-0.63 m/s, p = 0.78). CONCLUSIONS: ARFI with SWV measurement enables the quantification of normal and post irradiation elasticity of the masseter. Further studies on a larger population are required to validate the normal and pathologic values.
AIMS: The study proposes Acoustic Radiation Force Impulse (ARFI) assessment of the masseter muscle elasticity in the healthy population and in patients who have undergone head and neck radiation therapy. PATIENTS AND METHODS: Twenty-five healthy controls constituted group A, and 13 patients who had underwent radiotherapy (35Gy minimum) formed group B. ARFI was performed bilaterally in the periphery (P) and the muscle center (C), in relaxation and contraction. Means and standard deviations were obtained for the recorded shear waves velocities (SWV). RESULTS: For group A: in the relaxed right muscle C = 1.87±0.52 m/s and P = 1.96 ±0.55 m/s and in the left muscle C = 1.66 +/- 0.47 m/s, P = 1.67 +/-0.53 m/s. For group B, in relaxation, the right side presented C = 1.67 +/-0.6 m/s, P 1.72 +/-0.56 m/s, the left muscle C = 1.6 +/-0.34 m/s, P = 1.73 +/-0.37 m/s. There were no differences (p> 0.05) between P and C of both groups, regardless of the muscle state. The values for relaxation and contraction in A and B (merged values of the right and left) presented no differences (1.79+/-0.52 m/s vs 1.72 +/-0.73 m/s, p = 0.72 and 1.70 +/-0.48 m/s and vs 1.59 +/-0.77 m/s, p = 0.98). All measurements of group A vs B were not different (1.79 +/-0.52 m/s vs 1.65 +/-0.63 m/s, p = 0.78). CONCLUSIONS: ARFI with SWV measurement enables the quantification of normal and post irradiation elasticity of the masseter. Further studies on a larger population are required to validate the normal and pathologic values.