Zexin Kang, Xiaodong Wen, Chao Li, Jiang Sun, Jing Wang, Shuisheng Jian.
Abstract
A novel all-fiber sensing configuration for simultaneous measurements of temperature and strain based on the up-taper Mach-Zehnder interferometer (MZI) with an in-line embedded fiber Bragg grating (FBG) is proposed and experimentally demonstrated. This configuration consists of two up-tapers fabricated by an excessive fusion splicing method and a short segment of inscribed FBG. Due to the different responses of the up-taper MZI and the FBG to the uniform variation of temperature and strain, the simultaneous measurement for these two variables could be achieved by real-time monitoring the transmission spectrum. For 0.01 nm wavelength resolution, a resolution of 0.311°C in temperature can be achieved, and the average strain resolution is 10.07 με.Year: 2014 PMID: 24787597 DOI: 10.1364/AO.53.002691
Source DB: PubMed Journal: Appl Opt ISSN: 1559-128X Impact factor: 1.980