Literature DB >> 24784872

Reduction in mean deviation values in automated perimetry in eyes with multifocal compared to monofocal intraocular lens implants.

Marjan Farid1, Garrick Chak2, Sumit Garg2, Roger F Steinert2.   

Abstract

PURPOSE: To evaluate differences in mean deviation values in automated perimetry in healthy eyes with multifocal compared to monofocal intraocular lens (IOL) implants.
DESIGN: Prospective, age-matched, comparative analysis.
SETTING: Single-center, tertiary referral academic practice. PATIENT POPULATION: A total of 37 healthy eyes in 37 patients with bilateral multifocal (n=22) or monofocal (n=15) IOL implants were studied. INTERVENTION/OBSERVATION PROCEDURE: Humphrey Visual Field 10-2 testing was performed on all patients. MAIN OUTCOME MEASURES: Mean deviation (MD) and pattern standard deviation (PSD) numerical values were evaluated and compared between groups.
RESULTS: The average MD was -2.84 dB (SD 2.32) for the multifocal IOL group and -0.97 dB (SD 1.58) for the monofocal IOL group (P=.006). There was no significant difference in PSD between the 2 groups (P=.99). Eyes that had the visual field 10-2 testing≥6 months from time of IOL placement showed no improvement in MD when compared to eyes that were tested within 6 months from IOL placement.
CONCLUSION: Multifocal IOL implants cause significant nonspecific reduction in MD values on Humphrey Visual Field 10-2 testing that does not improve with time or neuroadaptation. Multifocal IOL implants may be inadvisable in patients where central visual field reduction may not be tolerated, such as macular degeneration, retinal pigment epithelium changes, and glaucoma.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 24784872     DOI: 10.1016/j.ajo.2014.04.017

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  4 in total

1.  Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses.

Authors:  Kazunori Hirasawa; Hikaru Ito; Yukari Ohori; Yui Takano; Nobuyuki Shoji
Journal:  Int J Ophthalmol       Date:  2017-10-18       Impact factor: 1.779

2.  Analysis of Korean Retinal Specialists' Opinions on Implanting Diffractive Multifocal Intraocular Lenses in Eyes with Underlying Retinal Diseases.

Authors:  Jung-Hwa Lee; Mingui Kong; Joon-Hong Sohn; Beom-Jin Cho; Kee-Yong Choi; Sang-Mok Lee
Journal:  J Clin Med       Date:  2022-03-26       Impact factor: 4.241

3.  Influence of implantation of diffractive trifocal intraocular lenses on standard automated perimetry.

Authors:  Jinhee Lee; Yosai Mori; Keiichiro Minami; Kazunori Miyata
Journal:  BMC Ophthalmol       Date:  2022-04-02       Impact factor: 2.209

4.  Influence of extended depth of focus intraocular lenses on visual field sensitivity.

Authors:  Makiko Takahashi; Chiemi Yamashiro; Takuya Yoshimoto; Yuka Kobayashi; Fumiaki Higashijima; Masaaki Kobayashi; Makoto Hatano; Manami Ohta; Tomohiko Nagai; Shinichiro Teranishi; Katsuyoshi Suzuki; Ryu Takabatake; Kazuhiro Kimura
Journal:  PLoS One       Date:  2020-09-14       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.