Literature DB >> 24784635

Pulsed magnetic field measurement system based on colossal magnetoresistance-B-scalar sensors for railgun investigation.

T Stankevič1, L Medišauskas1, V Stankevič1, S Balevičius1, N Żurauskienė1, O Liebfried2, M Schneider2.   

Abstract

A high pulsed magnetic field measurement system based on the use of CMR-B-scalar sensors was developed for the investigations of the electrodynamic processes in electromagnetic launchers. The system consists of four independent modules (channels) which are controlled by a personal computer. Each channel is equipped with a CMR-B-scalar sensor connected to the measurement device-B-scalar meter. The system is able to measure the magnitude of pulsed magnetic fields from 0.3 T to 20 T in the range from DC up to 20 kHz independently of the magnetic field direction. The measurement equipment circuit is electrically separated from the ground and shielded against low and high frequency electromagnetic noise. The B-scalar meters can be operated in the presence of ambient pulsed magnetic fields with amplitudes up to 0.2 T and frequencies higher than 1 kHz. The recorded signals can be transmitted to a personal computer in a distance of 25 m by means of a fiber optic link. The system was tested using the electromagnetic railgun RAFIRA installed at the French-German Research Institute of Saint-Louis, France.

Year:  2014        PMID: 24784635     DOI: 10.1063/1.4870280

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  3 in total

1.  Enhancement of Room-Temperature Low-Field Magnetoresistance in Nanostructured Lanthanum Manganite Films for Magnetic Sensor Applications.

Authors:  Nerija Zurauskiene; Voitech Stankevic; Skirmantas Kersulis; Milita Vagner; Valentina Plausinaitiene; Jorunas Dobilas; Remigijus Vasiliauskas; Martynas Skapas; Mykola Koliada; Jaroslaw Pietosa; Andrzej Wisniewski
Journal:  Sensors (Basel)       Date:  2022-05-25       Impact factor: 3.847

2.  Room temperature Co-doped manganite/graphene sensor operating at high pulsed magnetic fields.

Authors:  Rasuole Lukose; Nerija Zurauskiene; Voitech Stankevic; Milita Vagner; Valentina Plausinaitiene; Gediminas Niaura; Skirmantas Kersulis; Saulius Balevicius; Eleonora Bolli; Alessio Mezzi; Saulius Kaciulis
Journal:  Sci Rep       Date:  2019-07-01       Impact factor: 4.379

3.  Nanostructured Manganite Films Grown by Pulsed Injection MOCVD: Tuning Low- and High-Field Magnetoresistive Properties for Sensors Applications.

Authors:  Voitech Stankevic; Nerija Zurauskiene; Skirmantas Kersulis; Valentina Plausinaitiene; Rasuole Lukose; Jonas Klimantavicius; Sonata Tolvaišienė; Martynas Skapas; Algirdas Selskis; Saulius Balevicius
Journal:  Sensors (Basel)       Date:  2022-01-13       Impact factor: 3.576