Literature DB >> 24782106

Identification of clinical yeasts by Vitek MS system compared with API ID 32 C.

M Teresa Durán-Valle1, Nuria Sanz-Rodríguez, Carmen Muñoz-Paraíso, María Almagro-Moltó, José Luis Gómez-Garcés.   

Abstract

We performed a clinical evaluation of the Vitek MS matrix-assisted laser desorption ionization-time-of-flight mass spectrometry (MALDI-TOF MS) system with the commercial database version 2.0 for rapid identification of medically important yeasts as compared with the conventional phenotypic method API ID 32 C. We tested 161 clinical isolates, nine isolates from culture collections and five reference strains. In case of discrepant results or no identification with one or both methods, molecular identification techniques were employed. Concordance between both methods was observed with 160/175 isolates (91.42%) and misidentifications by both systems occurred only when taxa were not included in the respective databases, i.e., one isolate of Candida etchellsii was identified as C. globosa by Vitek MS and two isolates of C. orthopsilosis were identified as C. parapsilosis by API ID 32 C. Vitek MS could not identify nine strains (5.14%) and API ID 32 C did not identify 13 (7.42%). Vitek MS was more reliable than API ID 32 C and reduced the time required for the identification of clinical isolates to only a few minutes.

Entities:  

Keywords:  MALDI; identification; yeasts

Mesh:

Year:  2014        PMID: 24782106     DOI: 10.1093/mmy/myt036

Source DB:  PubMed          Journal:  Med Mycol        ISSN: 1369-3786            Impact factor:   4.076


  3 in total

1.  Evaluation of a new matrix-assisted laser desorption/ionization time-of-flight mass spectrometry system for the identification of yeast isolation.

Authors:  Hyeyoung Lee; Ji-Hyun Park; Junsang Oh; Sungil Cho; Jehyun Koo; Ik Chun Park; Jiwoo Kim; Sehyun Park; Ji Seon Choi; So Youn Shin; Gi-Ho Sung; Jayoung Kim
Journal:  J Clin Lab Anal       Date:  2018-10-08       Impact factor: 2.352

2.  Comparative Assessment of Matrix-assisted Laser Desorption Ionization-time of Flight Mass Spectrometry (MALDI-TOF-MS) and Conventional Methods in the Identification of Clinically Relevant Yeasts.

Authors:  Suneeta Meena; Aroop Mohanty; Neelam Kaistha; U Sasirekha; Jitendra Meena
Journal:  Cureus       Date:  2021-06-11

3.  Association between Vitamin D and Candida-Associated Denture Stomatitis.

Authors:  Miranda Muhvić-Urek; Ema Saltović; Alen Braut; Daniela Kovačević Pavičić
Journal:  Dent J (Basel)       Date:  2020-10-21
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.