Literature DB >> 24780255

Estrogenic compounds determination in water samples by dispersive liquid-liquid microextraction and micellar electrokinetic chromatography coupled to mass spectrometry.

Giovanni D'Orazio1, María Asensio-Ramos2, Javier Hernández-Borges2, Salvatore Fanali3, Miguel Ángel Rodríguez-Delgado4.   

Abstract

In this work, a group of 12 estrogenic compounds, i.e., four natural sexual hormones (estrone, 17β-estradiol, 17α-estradiol and estriol), an exoestrogen (17α-ethynylestradiol), a synthetic stilbene (dienestrol), a mycotoxin (zearalenone) and some of their major metabolites (2-methoxyestradiol, α-zearalanol, β-zearalanol, α-zearalenol and β-zearalenol) have been separated and determined by micellar electrokinetic chromatography (MEKC) coupled to electrospray ion trap mass spectrometry. For this purpose, a background electrolyte containing an aqueous solution of 45 mM of perfluorooctanoic acid (PFOA) adjusted to pH 9.0 with an ammonia solution, as MS friendly surfactant, and methanol (10% (v/v)), as organic modifier, was used. To further increase the sensitivity, normal stacking mode was applied by injecting the sample dissolved in an aqueous solution of 11.5mM of ammonium PFO (APFO) at pH 9.0 containing 10% (v/v) of methanol for 25s. Dispersive liquid-liquid microextraction, using 110 μL of chloroform and 500 μL of acetonitrile as extraction and dispersion solvents, respectively, was employed to extract and preconcentrate the target analytes from different types of environmental water samples (mineral, run-off and wastewater) containing 30% (w/v) NaCl and adjusted to pH 3.0 with 1M HCl. The limits of detection achieved were in the range 0.04-1.10 μg/L. The whole method was validated in terms of linearity, precision, recovery and matrix effect for each type of water, showing determination coefficients higher than 0.992 for matrix-matched calibration and absolute recoveries in the range 43-91%.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Dispersive liquid–liquid microextraction; Estrogens; Mass spectrometry; Micellar electrokinetic chromatography; Water samples

Mesh:

Substances:

Year:  2014        PMID: 24780255     DOI: 10.1016/j.chroma.2014.04.005

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

Review 1.  Detection of contaminants in water supply: A review on state-of-the-art monitoring technologies and their applications.

Authors:  Syahidah Nurani Zulkifli; Herlina Abdul Rahim; Woei-Jye Lau
Journal:  Sens Actuators B Chem       Date:  2017-09-18       Impact factor: 7.460

2.  Application of Switchable Hydrophobicity Solvents for Extraction of Emerging Contaminants in Wastewater Samples.

Authors:  Guillermo Lasarte-Aragonés; Alejandro Álvarez-Lueje; Ricardo Salazar; Carla Toledo-Neira
Journal:  Molecules       Date:  2019-12-25       Impact factor: 4.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.