The clinical value of (18)F-FDG detection with a dual-head coincidence camera: a review.

I Ak1, J Blokland, E Pauwels, M Stokkel.   

Abstract

Positron emission tomography (PET) has evolved into a technique that can accurately determine the distribution of positron-emitting radionuclides. The addition of a coincidence detection mode to a standard dual-head detector system has resulted in the option of single-photon and annihilation coincidence detection. This new device for imaging fluorine-18 2-fluoro-2-deoxy-D-glucose ((18)F-FDG) accumulation in neoplasms became commercially available in 1994. Besides conventional low-energy imaging in the collimated single-photon mode, it offers a relatively inexpensive opportunity to perform uncollimated PET by switching to the coincidence acquisition mode. This review summarises the clinical value of (18)F-FDG detection with a dual-head coincidence camera in oncology. The results are compared with the overall results obtained using dedicated PET scanners. With respect to head and neck tumours, (18)F-FDG coincidence mode gamma camera imaging (CGI) yields results that are in agreement with those obtained with dedicated PET scanners. With regard to other malignancies, such as lung cancer, lymphoma and brain tumours, data in the literature are too scarce to draw any definite conclusions. In general, the results of (18)F-FDG CGI in tumours >15 mm seem to be comparable to those obtained with dedicated PET scanners, whereas in tumours <15 mm, the relative sensitivity of (18)F-FDG CGI is approximately 80%. Using attenuation correction, the diagnostic yield of (18)F-FDG CGI may increase. However, further clinical investigation is required to definitely establish its value in staging primary disease, therapy monitoring and assessment of tumour recurrence in clinical oncology.

Entities:  

Year:  2001        PMID: 24777543     DOI: 10.1007/s002590100501

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  3 in total

1.  Initial experience with a prototype dual-crystal (LSO/NaI) dual-head coincidence camera in oncology.

Authors:  Urvi Joshi; Otto S Hoekstra; Ronald Boellaard; Emile F I Comans; Pieter G H M Raijmakers; Rik J Pijpers; Steven D Miller; Gerrit J J Teule; Arthur van Lingen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-01-14       Impact factor: 9.236

2.  Optimisation of the OS-EM algorithm and comparison with FBP for image reconstruction on a dual-head camera: a phantom and a clinical 18F-FDG study.

Authors:  Fabrice Gutman; Isabelle Gardin; Nicolas Delahaye; Hervé Rakotonirina; Anne Hitzel; Alain Manrique; Dominique Le Guludec; Pierre Véra
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-09-23       Impact factor: 9.236

3.  Mathematical Simulation of Transport Kinetics of Tumor-Imaging Radiopharmaceutical 99mTc-MIBI.

Authors:  O N Shevtsova; V K Shevtsova
Journal:  Comput Math Methods Med       Date:  2017-06-15       Impact factor: 2.238

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.