Literature DB >> 24776914

EPR retrospective dosimetry with fingernails: report on first application cases.

Francois Trompier1, François Queinnec, Eric Bey, Thierry De Revel, Jean Jacques Lataillade, Isabelle Clairand, Marc Benderitter, Jean-François Bottollier-Depois.   

Abstract

For localized irradiation to hands, in case of sources accidentally handled, it is very difficult to estimate the dose distribution by calculation. Doses may reach several tens of grays, and the dose distribution is usually very heterogeneous. Until recently, doses in such situations could be estimated only by analysis of bone biopsies using Electron Paramagnetic Resonance (EPR) spectroscopy. This technique was used previously on surgical wastes or after amputation of a finger. In this case, the dose information was available in one or a few locations on the hand only, due to the limited number of biopsy fragments usually collected. The idea to measure free radicals (FRs) induced by radiation in nails to estimate a dose is not new, but up to now, no application cases were reported. As a matter of fact, the EPR analysis of nails is complex due to the presence of intrinsic signals and parasitic signals induced by the mechanical stress (when nails are collected), which overlaps the radio-induced components. In addition, the radio-induced FRs identified up to now are unstable and very sensitive to humidity. In these conditions, it was difficult to foresee any application for dosimetry with fingernails. Recently, stable radio-induced FRs in nails has been identified and an associated protocol for dose assessment developed. This protocol has been applied by the Institut de Radioprotection et de Sûreté Nucléaire on fingernail samples from victims of three different radiological accidents that occurred between 2008 and 2012 in different places.

Entities:  

Mesh:

Year:  2014        PMID: 24776914     DOI: 10.1097/HP.0000000000000110

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  11 in total

1.  The effect of sunlight and UV lamps on EPR signal in nails.

Authors:  Agnieszka Marciniak; Bartłomiej Ciesielski; Małgorzata Juniewicz; Anita Prawdzik-Dampc; Mirosław Sawczak
Journal:  Radiat Environ Biophys       Date:  2019-02-10       Impact factor: 1.925

2.  Electron paramagnetic resonance radiation dose assessment in fingernails of the victim exposed to high dose as result of an accident.

Authors:  Alexander Romanyukha; François Trompier; Ricardo A Reyes; Doran M Christensen; Carol J Iddins; Stephen L Sugarman
Journal:  Radiat Environ Biophys       Date:  2014-06-24       Impact factor: 1.925

3.  Comparison of Continuous Wave and Rapid Scan X-band Electron Paramagnetic Resonance of Irradiated Clipped Fingernails.

Authors:  Hanan Elajaili; Joseph McPeak; Alexander Romanyukha; Priyanka Aggarwal; Sandra S Eaton; Gareth R Eaton
Journal:  Radiat Prot Dosimetry       Date:  2016-09-02       Impact factor: 0.972

4.  Developments in Biodosimetry Methods for Triage With a Focus on X-band Electron Paramagnetic Resonance In Vivo Fingernail Dosimetry.

Authors:  Steven G Swarts; Jason W Sidabras; Oleg Grinberg; Dmitriy S Tipikin; Maciej M Kmiec; Sergey V Petryakov; Wilson Schreiber; Victoria A Wood; Benjamin B Williams; Ann Barry Flood; Harold M Swartz
Journal:  Health Phys       Date:  2018-07       Impact factor: 1.316

Review 5.  State-of-the-Art Advances in Radiation Biodosimetry for Mass Casualty Events Involving Radiation Exposure.

Authors:  Mary Sproull; Kevin Camphausen
Journal:  Radiat Res       Date:  2016-10-06       Impact factor: 2.841

Review 6.  Cutaneous and local radiation injuries.

Authors:  Carol J Iddins; Andrea L DiCarlo; Mark D Ervin; Eduardo Herrera-Reyes; Ronald E Goans
Journal:  J Radiol Prot       Date:  2022-01-12       Impact factor: 1.559

7.  POSSIBLE NATURE OF THE RADIATION-INDUCED SIGNAL IN NAILS: HIGH-FIELD EPR, CONFIRMING CHEMICAL SYNTHESIS, AND QUANTUM CHEMICAL CALCULATIONS.

Authors:  Dmitriy S Tipikin; Steven G Swarts; Jason W Sidabras; François Trompier; Harold M Swartz
Journal:  Radiat Prot Dosimetry       Date:  2016-08-13       Impact factor: 0.972

8.  Scientific research and product development in the United States to address injuries from a radiation public health emergency.

Authors:  Andrea L DiCarlo
Journal:  J Radiat Res       Date:  2021-09-13       Impact factor: 2.724

9.  Effects of water on fingernail electron paramagnetic resonance dosimetry.

Authors:  Tengda Zhang; Zhixin Zhao; Haiying Zhang; Hezheng Zhai; Shuzhou Ruan; Ling Jiao; Wenyi Zhang
Journal:  J Radiat Res       Date:  2016-06-24       Impact factor: 2.724

10.  Evaluating the Potential of Q-Band ESR Spectroscopy for Dose Reconstruction of Fossil Tooth Enamel.

Authors:  Verónica Guilarte; François Trompier; Mathieu Duval
Journal:  PLoS One       Date:  2016-03-01       Impact factor: 3.240

View more