Literature DB >> 24772262

Mechanical evaluation and fem analysis of stress in fixed partial dentures zirconium-ceramic.

P L Cardelli1, V Vertucci2, F Balestra2, M Montani2, C Arcuri1.   

Abstract

OBJECTIVE: Over the last several years, the Finite Element Analysis (FEM) has been widely recognized as a reference method in different fields of study, to simulate the distribution of mechanical stress, in order to evaluate the relative distribution of loads of different nature. The aim of this study is to investigate through the FEM analysis the stress distribution in fixed prostheses that have a core in Zirconia and a ceramic veneer supported by implants.
MATERIALS AND METHODS: In this work we investigated the mechanical flexural strength of a ceramic material (Noritake(®)) and a of zirconium framework (Zircodent(®)) and the effects of the manufacturing processes of the material commonly performed during the production of fixed prostheses with CAD/CAM technology. Specifically three point bending mechanical tests were performed (three-point-bending) (1-3), using a machine from Test Equipment Instron 5566(®), on two structures in zirconium framework-ceramic (structures supported by two implant abutments with pontic elements 1 and 2). A further in-depth analysis on the mechanical behavior in flexure of the specimens was conducted carrying out FEM studies in order to compare analog and digital data.
RESULTS: The analysis of the data obtained showed that the stresses are distributed in a different way according to the intrinsic elasticity of the structure. The analysis of FPD with four elements, the stresses are mainly concentrated on the surface of the load, while, in the FPD of three elements, much more rigid, the stresses are concentrated near the inner margins of the abutments. The concentration of many stresses in this point could be correlated to chipping (4) that is found in the outer edges of the structure, as a direct result of the ceramic brittleness which opposes the resilience of the structure subjected to bending.
CONCLUSIONS: The analysis of the UY linear displacement confirms previous data, showing, in a numerical way, that the presence of the ceramic is related to the lowering of the structure. So, the reference values are those of the linear lowering obtained in the Mechanical Test and in our FEM analysis. zirconium framework with four elements 4,227 10(-2)mm.zirconium framework with ceramic structure with four elements 2,266 10(-2) mm.That suggests that the presence of ceramics halves the flexion capabilities of the prosthetic materials.

Entities:  

Keywords:  CAD-CAM; FEM; chipping; fixed-partial-dentures; mechanical evaluation; stress; zirconium-ceramic

Year:  2014        PMID: 24772262      PMCID: PMC3982301     

Source DB:  PubMed          Journal:  Oral Implantol (Rome)        ISSN: 1974-5648


  8 in total

1.  The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic.

Authors:  T Kosmac; C Oblak; P Jevnikar; N Funduk; L Marion
Journal:  Dent Mater       Date:  1999-11       Impact factor: 5.304

Review 2.  Survival and complications of zirconia-based fixed dental prostheses: a systematic review.

Authors:  Ariel J Raigrodski; Matthew B Hillstead; Graham K Meng; Kwok-Hung Chung
Journal:  J Prosthet Dent       Date:  2012-03       Impact factor: 3.426

3.  In vitro evaluation of low-temperature aging effects and finishing procedures on the flexural strength and structural stability of Y-TZP dental ceramics.

Authors:  Harry P Papanagiotou; Steven M Morgano; Russell A Giordano; Richard Pober
Journal:  J Prosthet Dent       Date:  2006-09       Impact factor: 3.426

Review 4.  Non-carious cervical tooth surface loss: a literature review.

Authors:  Ian Wood; Zynab Jawad; Carl Paisley; Paul Brunton
Journal:  J Dent       Date:  2008-07-25       Impact factor: 4.379

5.  Abfraction: 3D analysis by means of the finite element method.

Authors:  Allahyar Geramy; Farahnaz Sharafoddin
Journal:  Quintessence Int       Date:  2003 Jul-Aug       Impact factor: 1.677

6.  Mechanical evaluation of an implant-abutment self-locking taper connection: finite element analysis and experimental tests.

Authors:  Gianpaolo Sannino; Alberto Barlattani
Journal:  Int J Oral Maxillofac Implants       Date:  2013 Jan-Feb       Impact factor: 2.804

7.  3D finite element non linear analysis on the stress state at bone-implant interface in dental osteointegrated implants.

Authors:  G Sannino; G Marra; L Feo; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2011-01-13

8.  The stress analysis of human teeth.

Authors:  R W Thresher; G E Saito
Journal:  J Biomech       Date:  1973-09       Impact factor: 2.712

  8 in total
  1 in total

1.  Three-point bending test simulation on implant fpds with a bio-faithful model.

Authors:  V Vertucci; M Montani; C Arcuri; P Cardelli
Journal:  Oral Implantol (Rome)       Date:  2017-04-10
  1 in total