Literature DB >> 24771758

Right and left ventricular mechanics and interaction late after balloon valvoplasty for pulmonary stenosis.

Shu-Juan Li1, Hong-Kui Yu2, Sophia J Wong3, Yiu-Fai Cheung4.   

Abstract

AIMS: This study sought to explore right (RV) and left ventricular (LV) mechanics and ventricular-ventricular interaction in adolescents and young adults late after percutaneous balloon pulmonary valvoplasty (PBPV) for valvar pulmonary stenosis (PS). METHODS AND
RESULTS: Potential late effects of PS despite PBPV on cardiac mechanics have not been well defined. Thirty-one patients aged 20.2 ± 7.6 years were studied at 18 ± 6 years after PBPV. Ventricular myocardial deformation was determined using speckle tracking echocardiography, while RV and LV volumes and ejection fraction as well as LV systolic dyssynchrony index were assessed by three-dimensional echocardiography. The results were compared with those of 30 controls. Pulmonary regurgitation, mostly trivial to mild, was present in 90% (28/31) of patients. Compared with controls, patients had significantly greater RV end-diastolic (P < 0.001), RV end-systolic (P < 0.001), and LV end-systolic (P = 0.04) volumes as well as lower LV ejection fraction (P < 0.001). For deformation, patients had significantly reduced RV longitudinal systolic strain (P = 0.004), decreased LV circumferential systolic strain (P < 0.001), and strain rate (P = 0.001) as well as greater LV mechanical dyssynchrony (P < 0.001). In patients, RV end-diastolic and end-systolic volumes correlated with LV circumferential strain (r = -0.47, P = 0.008 and r = -0.36, P = 0.049, respectively) and dyssynchrony (r = 0.53, P = 0.002 and r = 0.49, P = 0.005, respectively). Patients who had PBPV at age ≤1 year had ventricular deformation indices similar to those who had interventions beyond 1 year.
CONCLUSION: Impaired RV and LV mechanics and adverse ventricular-ventricular interaction occur in adolescents and young adults late after balloon valvoplasty for isolated valvar PS. Published on behalf of the European Society of Cardiology. All rights reserved.
© The Author 2014. For permissions please email: journals.permissions@oup.com.

Entities:  

Keywords:  Percutaneous balloon pulmonary valvoplasty; Pulmonary stenosis; Ventricular interaction; Ventricular mechanics

Mesh:

Year:  2014        PMID: 24771758     DOI: 10.1093/ehjci/jeu058

Source DB:  PubMed          Journal:  Eur Heart J Cardiovasc Imaging        ISSN: 2047-2404            Impact factor:   6.875


  2 in total

1.  Left Ventricular Dysfunction Following Neonatal Pulmonary Valve Balloon Dilation for Pulmonary Atresia or Critical Pulmonary Stenosis.

Authors:  Christina Ronai; Rahul H Rathod; Audrey C Marshall; Rebecca Oduor; Kimberlee Gauvreau; Steven D Colan; David W Brown
Journal:  Pediatr Cardiol       Date:  2015-03-13       Impact factor: 1.655

2.  Assessment of Biventricular Myocardial Function with 2-Dimensional Strain and Conventional Echocardiographic Parameters: A Comparative Analysis in Healthy Infants and Patients with Severe and Critical Pulmonary Stenosis.

Authors:  Liliana Gozar; Mihaela Iancu; Horea Gozar; Anca Sglimbea; Andreea Cerghit Paler; Dorottya Gabor-Miklosi; Rodica Toganel; Amalia Făgărășan; Diana Ramona Iurian; Daniela Toma
Journal:  J Pers Med       Date:  2022-01-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.