Literature DB >> 24769630

Assessment of improved motion-sensitized driven equilibrium (iMSDE) for multi-contrast vessel wall screening.

Makoto Obara1, Marc Van Cauteren, Masatoshi Honda, Yutaka Imai, Kagayaki Kuroda.   

Abstract

PURPOSE: We assessed the improved motion-sensitized driven equilibrium (iMSDE) technique for multiple contrast 3-dimensional vessel wall imaging at 3T.
METHODS: Carotid images were obtained using iMSDE combined with turbo field echo (iMSDE-TFE) and conventional double inversion-recovery turbo spin-echo (DIR-TSE) in 5 healthy adult subjects. The tissue signal-to-noise efficiency (SNReff), SNR divided by the square root of scan time, lumen-tissue contrast-to-noise efficiency (CNReff), CNR divided by the square root of scan time, and tissue signal intensity ratio (SIR) were measured in both techniques and compared.
RESULTS: The iMSDE-TFE had higher SNReff and CNReff (P < 0.01) and strong correlation in SIR (R = 0.92) compared to DIR-TSE.
CONCLUSION: The iMSDE-TFE sequence is an efficient technique for vessel wall screening.

Mesh:

Year:  2014        PMID: 24769630     DOI: 10.2463/mrms.2013-0036

Source DB:  PubMed          Journal:  Magn Reson Med Sci        ISSN: 1347-3182            Impact factor:   2.471


  4 in total

1.  Three-dimensional black-blood contrast-enhanced MRI improves detection of intraluminal thrombi in patients with acute ischaemic stroke.

Authors:  Won Jang; Hyo Sung Kwak; Gyung Ho Chung; Seung Bae Hwang
Journal:  Eur Radiol       Date:  2018-03-19       Impact factor: 5.315

2.  Improved motion-sensitized driven-equilibrium preparation for 3D turbo spin echo T1 weighted imaging after gadolinium administration for the detection of brain metastases on 3T MRI.

Authors:  Sangjoon Lee; Dong Woo Park; Ji Young Lee; Young-Jun Lee; Taeyoon Kim
Journal:  Br J Radiol       Date:  2016-05-17       Impact factor: 3.039

3.  Optimization of improved motion-sensitized driven-equilibrium (iMSDE) blood suppression for carotid artery wall imaging.

Authors:  Chengcheng Zhu; Martin J Graves; Jianmin Yuan; Umar Sadat; Jonathan H Gillard; Andrew J Patterson
Journal:  J Cardiovasc Magn Reson       Date:  2014-08-09       Impact factor: 5.364

4.  Efficacy of Maximum Intensity Projection of Contrast-Enhanced 3D Turbo-Spin Echo Imaging with Improved Motion-Sensitized Driven-Equilibrium Preparation in the Detection of Brain Metastases.

Authors:  Yun Jung Bae; Byung Se Choi; Kyung Mi Lee; Yeon Hong Yoon; Leonard Sunwoo; Cheolkyu Jung; Jae Hyoung Kim
Journal:  Korean J Radiol       Date:  2017-05-19       Impact factor: 3.500

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.