Literature DB >> 24769420

Circumferential distribution of the neointima at six-month and two-year follow-up after a bioresorbable vascular scaffold implantation: a substudy of the ABSORB Cohort B Clinical Trial.

Christos V Bourantas1, Vasim Farooq, Yaojun Zhang, Takashi Muramatsu, Bill D Gogas, Leif Thuesen, Dougal McClean, Bernard Chevalier, Stephan Windecker, Jacques Koolen, John Ormiston, Robert Whitbourn, Cecile Dorange, Richard Rapoza, Yoshinobu Onuma, Hector M Garcia-Garcia, Patrick W Serruys.   

Abstract

AIMS: To investigate the extent and the circumferential distribution of the neointima tissue developed following an Absorb bioresorbable vascular scaffold (BVS) implantation. METHODS AND
RESULTS: Twenty-three patients who were treated with the Absorb BVS and had optical coherence tomographic examination after scaffold implantation, at six-month and at two-year follow-up, were included in the current analysis. The lumen and the scaffold borders were detected and the circumferential thickness of the neointima was measured at one degree intervals. The symmetry of the neointima was defined as: minimum/maximum thickness. The lumen area was decreased at six months compared to baseline but it did not change between six-month and two-year follow-up (baseline: 7.49 [6.13-8.00] mm², six months: 6.31 (4.75-7.06) mm², two years: 6.01 [4.67-7.11] mm², p=0.373). However, the mean neointima thickness (six months: 189 [173-229] m, two years: 258 [222-283] m, p<0.0001) and the symmetry index of the neointima (six months: 0.06 [0.02-0.09], two years: 0.27 [0.24-0.36], p<0.0001) were increased at two years. Full circumferential coverage of the vessel wall by neointima tissue was seen in 91% of the studied frames at two years.
CONCLUSIONS: This study demonstrates that after an Absorb BVS implantation neointima tissue develops that covers almost the whole circumference of the vessel wall. In contrast to the metallic stents, the neointima tissue does not compromise the luminal dimensions. Further research is required to evaluate the neointimal characteristics and assess the potential value of the device in passivating high-risk plaques.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 24769420     DOI: 10.4244/EIJY14M04_11

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  3 in total

1.  Implications of a bioresorbable vascular scaffold implantation on vessel wall strain of the treated and the adjacent segments.

Authors:  Christos V Bourantas; Hector M Garcia-Garcia; Carlos A M Campos; Yao-Jun Zhang; Takashi Muramatsu; Marie-Angèle Morel; Shimpei Nakatani; Xingyu Gao; Yun-Kyeong Cho; Yuki Isibashi; Frank J H Gijsen; Yoshinobu Onuma; Patrick W Serruys
Journal:  Int J Cardiovasc Imaging       Date:  2014-01-24       Impact factor: 2.357

Review 2.  Atherothrombosis in Acute Coronary Syndromes-From Mechanistic Insights to Targeted Therapies.

Authors:  Chinmay Khandkar; Mahesh V Madhavan; James C Weaver; David S Celermajer; Keyvan Karimi Galougahi
Journal:  Cells       Date:  2021-04-10       Impact factor: 6.600

Review 3.  Everolimus-eluting stent platforms in percutaneous coronary intervention: comparative effectiveness and outcomes.

Authors:  Vasileios F Panoulas; Ioannis Mastoris; Klio Konstantinou; Maurizio Tespili; Alfonso Ielasi
Journal:  Med Devices (Auckl)       Date:  2015-07-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.