Literature DB >> 24767907

Objective assessment of nuclear cataract: comparison of double-pass and Scheimpflug systems.

Sung A Lim1, Jehyung Hwang1, Kyu-Yeon Hwang1, So-Hyang Chung2.   

Abstract

PURPOSE: To compare the objective assessment of lens density by 2 systems (double-pass Optical Quality Analysis System and Pentacam Scheimpflug) in eyes with age-related nuclear cataract.
SETTING: Department of Ophthalmology and Visual Science, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea.
DESIGN: Cross-sectional study.
METHODS: In eyes with age-related nuclear cataract, the objective lens density (0 to 100 points) was determined using the Scheimpflug system while subjective grading was achieved using the Lens Opacities Classification System III (LOCS III). The objective scatter index (OSI) (0 to 25) was assessed using the double-pass system.
RESULTS: This study enrolled 47 patients (70 eyes). The mean OSI was 4.08 ± 2.22 (SD), and the mean Scheimpflug-measured lens density was 16.44 ± 4.36; the 2 parameters were correlated (r = 0.764, P<.01). There was a positive linear correlation between the OSI and LOCS III grading scores for nuclear opalescence and nuclear color (r = 0.772 and r = 0.752, respectively; P<.01). The cumulated dissipated energy (CDE) was strongly correlated with the OSI (r = 0.768) and Scheimpflug-measured lens density (r = 0.753).
CONCLUSIONS: The OSI based on the double-pass system was correlated with the Scheimpflug-measured lens density, subjective lens grading, and CDE. The OSI may improve the preoperative evaluation of nuclear cataract and help predict phacodynamics in cataract surgery.
Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 24767907     DOI: 10.1016/j.jcrs.2013.10.032

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  15 in total

1.  Three-dimensional visualization of opacifications in the murine crystalline lens by in vivo optical coherence tomography.

Authors:  Pablo Eugui; Danielle J Harper; Stefan Kummer; Antonia Lichtenegger; Johanna Gesperger; Tanja Himmel; Marco Augustin; Conrad W Merkle; Martin Glösmann; Bernhard Baumann
Journal:  Biomed Opt Express       Date:  2020-03-19       Impact factor: 3.732

2.  Correlation between different Scheimpflug-based lens densitometry analysis and effective phacoemulsification time in mild nuclear cataracts.

Authors:  Fernando Faria-Correia; Bernardo Lopes; Tiago Monteiro; Nuno Franqueira; Renato Ambrósio
Journal:  Int Ophthalmol       Date:  2017-05-26       Impact factor: 2.031

3.  Effects of hormone replacement therapy on lens opacity, serum inflammatory cytokines, and antioxidant levels.

Authors:  Donghyun Jee; Sang Hee Park; Ho Sik Hwang; Hyun Seung Kim; Man Soo Kim; Eun Chul Kim
Journal:  Ann Med       Date:  2021-12       Impact factor: 4.709

4.  Application of different Scheimpflug-based lens densitometry methods in phacodynamics prediction.

Authors:  Fernando Faria-Correia; Bernardo T Lopes; Isaac C Ramos; Tiago Monteiro; Nuno Franqueira; Renato Ambrósio
Journal:  Clin Ophthalmol       Date:  2016-04-06

5.  Assessment of Optical Quality at Different Contrast Levels in Pseudophakic Eyes.

Authors:  Chang Won Park; Hyojin Kim; Choun-Ki Joo
Journal:  J Ophthalmol       Date:  2016-01-28       Impact factor: 1.909

6.  Utility of the optical quality analysis system for decision-making in cataract surgery.

Authors:  Jin Sun Hwang; Yoon Pyo Lee; Seok Hyun Bae; Ha Kyoung Kim; Kayoung Yi; Young Joo Shin
Journal:  BMC Ophthalmol       Date:  2018-09-03       Impact factor: 2.209

7.  Quantitative Analysis of Lens Nuclear Density Using Optical Coherence Tomography (OCT) with a Liquid Optics Interface: Correlation between OCT Images and LOCS III Grading.

Authors:  You Na Kim; Jin Hyoung Park; Hungwon Tchah
Journal:  J Ophthalmol       Date:  2016-08-29       Impact factor: 1.909

8.  A comparison of mesopic visual acuity and objective visual quality following cataract surgery with hydrophobic acrylic intraocular lenses.

Authors:  George Hh Beiko; Miso Gostimir; Lila Haj-Ahmad
Journal:  Clin Ophthalmol       Date:  2017-04-07

9.  Assessing the correlation between swept-source optical coherence tomography lens density pattern analysis and best-corrected visual acuity in patients with cataracts.

Authors:  Hugo Bourdon; Liem Trinh; Mathieu Robin; Christophe Baudouin
Journal:  BMJ Open Ophthalmol       Date:  2021-05-13

10.  Visual Quality Assessment of Posterior Capsule Opacification Using Optical Quality Analysis System (OQAS).

Authors:  Hui Zhang; Jing Wang
Journal:  J Ophthalmol       Date:  2017-10-03       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.