Literature DB >> 24767711

New-generation stent grafts for endovascular management of thoracic pseudoaneurysms after aortic coarctation repair.

Anisha H Perera1, Nung Rudarakanchana1, Mohamad Hamady2, Elika Kashef3, Maziar Mireskandari4, Anselm Uebing5, Nicholas J Cheshire1, Colin D Bicknell6.   

Abstract

OBJECTIVE: Late thoracic aneurysms develop in 5% to 12% of patients having undergone open repair for coarctation of the aorta (CoA). We report our early results for thoracic endovascular aortic repair for pseudoaneurysms after CoA repair.
METHODS: From 2008 to 2013, data regarding demographics, aneurysm morphology, procedure, and follow-up were collected prospectively on all patients treated for pseudoaneurysms after CoA repair. Retrospective analysis of identified patients was then performed.
RESULTS: Thirteen patients (six men, seven women) were treated. Patients were a median age, 45 years (interquartile range (IQR), 39-56; range, 27-66 years, and the median time after CoA repair to aneurysm treatment was 34 years (IQR, 24-40 years). All patients had saccular pseudoaneurysms of the aortic arch, with a median aneurysm size of 4.1 cm (IQR, 3.4-5.1 cm). The left subclavian artery (LSCA) was involved in 10 patients and was occluded at presentation in three. Four patients had concurrent LSCA revascularization with carotid-subclavian bypass, one had aortic arch hybrid repair, and the LSCA was intentionally covered in two patients. Patients underwent thoracic endovascular aortic repair using the conformable TAG (6 of 13; W. L. Gore & Associates, Flagstaff, Ariz), Valiant device (4 of 13; Medtronic, Minneapolis, Minn), and a custom-made Relay endograft with LSCA scallop (4 of 13; Bolton Medical, Barcelona, Spain). Technical success was 100%, with satisfactory deployment of the stent grafts in all patients. There was no 30-day mortality, stroke, or paraplegia. Median follow-up was 15 months (IQR, 9-19 months; range, 1-67 months). Two type II endoleaks from an intercostal artery were managed conservatively, and one type Ib endoleak was treated successfully with distal stent extension.
CONCLUSIONS: In this cohort, new-generation stent grafts have good early clinical and radiologic outcomes, avoiding the need for redo open surgery. Management of the LSCA can be tailored to individual patients with new stent graft technology. Long-term follow-up of these patients is crucial to understanding whether endovascular management of this cohort is acceptable.
Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 24767711     DOI: 10.1016/j.jvs.2014.02.050

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  4 in total

Review 1.  Coarctation repair-redo challenges in the adults: what to do?

Authors:  Erik Beckmann; Arminder S Jassar
Journal:  J Vis Surg       Date:  2018-04-23

Review 2.  Most Coarctations, Recoarctations, and Coarctation-Related Aneurysms Should Be Treated Endovascularly.

Authors:  Edgar Luis Galiñanes; Zvonimir Krajcer
Journal:  Aorta (Stamford)       Date:  2015-08-01

3.  Assessment of CardiOvascular Remodelling following Endovascular aortic repair through imaging and computation: the CORE prospective observational cohort study protocol.

Authors:  Foeke J H Nauta; Arnoud V Kamman; El-Sayed H Ibrahim; Prachi P Agarwal; Bo Yang; Karen Kim; David M Williams; Joost A van Herwaarden; Frans L Moll; Kim A Eagle; Santi Trimarchi; Himanshu J Patel; C Alberto Figueroa
Journal:  BMJ Open       Date:  2016-11-17       Impact factor: 2.692

4.  Successful hybrid TEVAR for distal anastomotic pseudoaneurysm and coarctation following previous palliative left subclavian artery to descending aorta bypass: A case report.

Authors:  Takasumi Goto; Hiroyuki Nishi; Mutsunori Kitahara; Satoshi Sakakibara; Yumi Kakizawa
Journal:  Int J Surg Case Rep       Date:  2020-08-15
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.