Literature DB >> 24767098

Stereotactic radiotherapy using tomotherapy for early-stage non-small cell lung carcinoma: analysis of intrafraction tumour motion.

Drexell Hunter Boggs1, Steven Feigenberg, Robert Walter, Dennis Wissing, Bijal Patel, Terry Wu, Lane Rosen.   

Abstract

INTRODUCTION: Intrafraction tumour motion in helical tomotherapy was investigated by comparing pre- and mid-fraction CT scans in patients with early non-small cell lung carcinoma (NSCLC) to assess the efficacy of a 7-mm margin around gross tumour volumes (GTVs) in stereotactic body radiation therapy (SBRT).
METHODS: Thirty patients with early-stage NSCLC received SBRT in four or five fractions for a total of 141 treatments. A slow positron emission tomography/CT scan was fused with the simulation CT to determine the GTV. A planning target volume was created by placing an isotropic margin of 7 mm around the GTV. Data were retrospectively analyzed to assess translational tumour positional changes along the x, y and z axes and vector changes in millimeters from the pretreatment megavoltage (MV)-CT to the mid-fraction MV-CT.
RESULTS: Average movements for all 141 treatment days along the x, y and z axes were 0.5 ± 2.3, -0.3 ± 3.0 and 0.9 ± 3.0 mm, respectively. Average movements for each patient along the x, y and z axes were 0.5 ± 1.5, -0.2 ± 2.0 and 0.9 ± 1.9 mm, respectively. Average vector displacement was 4.3 ± 2.4 mm for all treatment days and 4.2 ± 1.7 mm for each patient. Of 141 treatments, 137 (97.2%) fell within 7.0 mm in all axes.
CONCLUSION: The addition of a 7-mm margin to the GTV for patients receiving SBRT for NSCLC using tomotherapy is adequate to account for tumour movement. Mid-fraction CT scans proved to be valuable in assessing intrafraction tumour motion.
© 2014 The Royal Australian and New Zealand College of Radiologists.

Entities:  

Keywords:  SBRT; early-stage lung cancer; intrafraction; tomotherapy; tumour motion

Mesh:

Year:  2014        PMID: 24767098     DOI: 10.1111/1754-9485.12179

Source DB:  PubMed          Journal:  J Med Imaging Radiat Oncol        ISSN: 1754-9477            Impact factor:   1.735


  2 in total

1.  Influence of different treatment techniques and clinical factors over the intrafraction variation on lung stereotactic body radiotherapy.

Authors:  M Rico; E Martínez; S Pellejero; B Bermejo; P Navarrete; M Barrado; M Campo; F Mañeru; E Villafranca; J Aristu
Journal:  Clin Transl Oncol       Date:  2016-01-12       Impact factor: 3.405

2.  Dose delivery accuracy on helical tomotherapy for 4-dimensional tumor motion - a phantom study.

Authors:  Raghavendra Holla; David Khanna; V K Sathiya Narayanan
Journal:  Rep Pract Oncol Radiother       Date:  2021-06-09
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.