Literature DB >> 24766419

Direct electron transfer of glucose oxidase-boron doped diamond interface: a new solution for a classical problem.

Yan-Feng Bai1, Tai-Bin Xu, John H T Luong, Hui-Fang Cui.   

Abstract

A planar boron-doped diamond (BDD) electrode was treated with KOH and functionalized with 3-aminopropyltriethoxysilane (APTES) to serve as a biosensing platform for biomolecule immobilization with glucose oxidase (GOx) as a test model. The free amino groups of GOx and APTES were cross-linked by glutaraldehyde (X), a bifunctional chemical to form a stable enzyme layer (GOx-X-APTES) on BDD. Micrographs obtained by scanning electron microscopy revealed that a mesoporous structure uniformly covered the BDD surface. Cyclic voltammetry of GOx immobilized showed a pair of well-defined redox peaks in neutral phosphate buffer solution, corresponding to the direct electron transfer of GOx. The apparent heterogeneous electron transfer rate constant of the immobilized GOx was estimated to be 8.85 ± 0.47 s(-1), considerably higher than the literature reported values. The determination of glucose was carried out by amperometry at -0.40 V, and the developed biosensor showed good reproducibility and stability with a detection limit of 20 μM. Both ascorbic and uric acids at normal physiological conditions did not provoke any signals. The dynamic range of glucose detection was further extended by covering the enzyme electrode with a thin Nafion layer. The Nafion/GOx-X-APTES/BDD biosensor showed excellent stability, a detection limit of 30 μM, a linear range between 35 μM and 8 mM, and a dynamic range up to 14 mM. Such analytical performances were compared favorably with other complicated sensing schemes using nanomaterials, redox polymers, and nanowires. The APTES-functionalized BDD could be easily extended to immobilize other redox enzymes or proteins of interests.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24766419     DOI: 10.1021/ac501143e

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  8 in total

Review 1.  A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors.

Authors:  Siva Kumar Krishnan; Eric Singh; Pragya Singh; Meyya Meyyappan; Hari Singh Nalwa
Journal:  RSC Adv       Date:  2019-03-18       Impact factor: 4.036

2.  Rational design of binder-free noble metal/metal oxide arrays with nanocauliflower structure for wide linear range nonenzymatic glucose detection.

Authors:  Zhenzhen Li; Yanmei Xin; Zhonghai Zhang; Hongjun Wu; Peng Wang
Journal:  Sci Rep       Date:  2015-06-12       Impact factor: 4.379

3.  Direct electrochemistry of glucose oxidase on novel free-standing nitrogen-doped carbon nanospheres@carbon nanofibers composite film.

Authors:  Xueping Zhang; Dong Liu; Libo Li; Tianyan You
Journal:  Sci Rep       Date:  2015-05-06       Impact factor: 4.379

Review 4.  Electrochemical sensors and biosensors based on nanomaterials and nanostructures.

Authors:  Chengzhou Zhu; Guohai Yang; He Li; Dan Du; Yuehe Lin
Journal:  Anal Chem       Date:  2014-12-19       Impact factor: 6.986

5.  Chitosan-Covered Pd@Pt Core-Shell Nanocubes for Direct Electron Transfer in Electrochemical Enzymatic Glucose Biosensor.

Authors:  Siva Kumar Krishnan; Evgen Prokhorov; Daniel Bahena; Rodrigo Esparza; M Meyyappan
Journal:  ACS Omega       Date:  2017-05-08

Review 6.  Enzyme-Based Biosensors: Tackling Electron Transfer Issues.

Authors:  Paolo Bollella; Evgeny Katz
Journal:  Sensors (Basel)       Date:  2020-06-21       Impact factor: 3.576

7.  Rationally designed naphthyl substituted amine functionalized ionic liquid platform for covalent immobilization and direct electrochemistry of hemoglobin.

Authors:  K Theyagarajan; Duraisamy Saravanakumar; Sellappan Senthilkumar; Kathavarayan Thenmozhi
Journal:  Sci Rep       Date:  2019-07-18       Impact factor: 4.379

8.  Au nanoparticles modified CuO nanowireelectrode based non-enzymatic glucose detection with improved linearity.

Authors:  Ashwini Kumar Mishra; Deepak Kumar Jarwal; Bratindranath Mukherjee; Amit Kumar; Smrity Ratan; Manas Ranjan Tripathy; Satyabrata Jit
Journal:  Sci Rep       Date:  2020-07-10       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.