Literature DB >> 24764066

Comparative study of nJ- and μJ-energy level femtosecond lasers: evaluation of flap adhesion strength, stromal bed quality, and tissue responses.

Andri K Riau1, Yu-Chi Liu2, Nyein C Lwin1, Heng P Ang1, Neil Y S Tan1, Gary H F Yam1, Donald T Tan1, Jodhbir S Mehta3.   

Abstract

PURPOSE: To compare flap adhesion strength, stromal bed quality, and tissue responses after flap preparation using nJ- and μJ-energy level femtosecond lasers.
METHODS: All corneal flaps were created by either VisuMax laser (μJ-energy level) or femto-LDV (nJ-energy level). Flap adhesion strength in the rabbits was measured with a tension meter 1 and 2 months postoperatively. To investigate tissue responses to laser delivery, immunofluorescence staining and TUNEL assay were performed 4 and 24 hours postoperatively. To assess flap bed smoothness, human donor corneas were used. Surface irregularities were graded based on scanning electron microscopy results.
RESULTS: The flap adhesion strength in the VisuMax group at month 1 and 2 was 16.95 ± 1.45 kPa and 18.33 ± 1.81 kPa, respectively; and 12.31 ± 4.15 kPa and 13.85 ± 4.78 kPa in the LDV group, respectively. No significant difference was found between the groups. Fibronectin and apoptotic cells were largely absent at the central incision site in the LDV group, but were present in the VisuMax group. The smoothness of flap beds appeared similar for both groups. An observer scored the VisuMax group 8.00 ± 1.00 and the LDV group 7.33 ± 0.58 (P = 0.387).
CONCLUSIONS: The flap adhesion strength increased over time after treatment with both lasers. The nJ-energy pulses produced minimal wound healing reaction and apoptotic cells along the incision plane. The application of an nJ-energy laser, which can incise the cornea without inducing significant damage to cells and wound healing reaction, offers great potential at reducing scarring following incisional laser stromal surgery. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

Entities:  

Keywords:  LASIK; energy level; femtosecond laser; flap adhesion; wound healing

Mesh:

Year:  2014        PMID: 24764066     DOI: 10.1167/iovs.14-14434

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  24 in total

1.  Comparison of four methods of surface roughness assessment of corneal stromal bed after lamellar cutting.

Authors:  Clotilde Jumelle; Alina Hamri; Gregory Egaud; Cyril Mauclair; Stephanie Reynaud; Virginie Dumas; Sandrine Pereira; Thibaud Garcin; Philippe Gain; Gilles Thuret
Journal:  Biomed Opt Express       Date:  2017-10-12       Impact factor: 3.732

2.  Comparison of visual performance recovery after thin-flap LASIK with 4 femtosecond lasers.

Authors:  Jing Zhang; Yue-Hua Zhou; Yan Zheng; Qian Liu
Journal:  Int J Ophthalmol       Date:  2017-10-18       Impact factor: 1.779

3.  Repeatability and Reproducibility of Corneal Biometric Measurements Using the Visante Omni and a Rabbit Experimental Model of Post-Surgical Corneal Ectasia.

Authors:  Yu-Chi Liu; Aris Konstantopoulos; Andri K Riau; Raj Bhayani; Nyein C Lwin; Ericia Pei Wen Teo; Gary Hin Fai Yam; Jodhbir S Mehta
Journal:  Transl Vis Sci Technol       Date:  2015-04-28       Impact factor: 3.283

4.  Femtosecond laser-assisted excision of conjunctival melanocytic lesions: Cosmetic and long-term outcomes.

Authors:  Victoria Grace Dimacali; Yu-Chi Liu; Hon Shing Ong; Darren S J Ting; Jodhbir S Mehta
Journal:  Clin Exp Ophthalmol       Date:  2021-02-23       Impact factor: 4.207

5.  Comparison of intra-ocular pressure changes with liquid or flat applanation interfaces in a femtosecond laser platform.

Authors:  G P Williams; H P Ang; B L George; Y C Liu; G Peh; L Izquierdo; D T Tan; J S Mehta
Journal:  Sci Rep       Date:  2015-10-06       Impact factor: 4.379

6.  Effect of Intraoperative Corneal Stromal Pocket Irrigation in Small Incision Lenticule Extraction.

Authors:  Yu-Chi Liu; Lasitha Jayasinghe; Heng Pei Ang; Nyein Chan Lwin; Gary Hin Fai Yam; Jodhbir S Mehta
Journal:  Biomed Res Int       Date:  2015-07-27       Impact factor: 3.411

7.  New instruments for lenticule extraction in small incision lenticule extraction (SMILE).

Authors:  Yu-Chi Liu; Tarak Pujara; Jodhbir S Mehta
Journal:  PLoS One       Date:  2014-12-01       Impact factor: 3.240

Review 8.  Advances in refractive corneal lenticule extraction.

Authors:  Matthias Fuest; Jodhbir S Mehta
Journal:  Taiwan J Ophthalmol       Date:  2021-04-24

9.  Decellularization of human stromal refractive lenticules for corneal tissue engineering.

Authors:  Gary Hin-Fai Yam; Nur Zahirah Binte M Yusoff; Tze-Wei Goh; Melina Setiawan; Xiao-Wen Lee; Yu-Chi Liu; Jodhbir S Mehta
Journal:  Sci Rep       Date:  2016-05-23       Impact factor: 4.379

10.  The effects of a low-energy, high frequency liquid optic interface femtosecond laser system on lens capsulotomy.

Authors:  Geraint P Williams; Ben L George; Yoke R Wong; Xin-Yi Seah; Heng-Pei Ang; Mun Kitt A Loke; Shian Chao Tay; Jod S Mehta
Journal:  Sci Rep       Date:  2016-04-19       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.