Abstract

BACKGROUND AND AIM OF THE STUDY: Transcatheter aortic valve implantation (TAVI) is contraindicated in the presence of an ascending aortic aneurysm. Our aim was to design a composite endovascular device enabling ascending aortic repair and TAVI.
METHODS: From 2007 to 2013, among 1196 patients with severe aortic stenosis screened for TAVI, 79 nonbicuspid patients had ascending aortic diameter >45 mm. Proximal aortic geometry was assessed in those with computed tomography angiography.
RESULTS: All together, 51 patients (35 males, aged 85 ± 8 years; 19 TAVI, 10 open Wheat procedures, 22 managed conservatively) were included. The required annular diameter for implantation of currently available TAVI prostheses was met in 41% (21/51). Novel prosthetic valves appropriate for annular range up to 30 mm would extend device applicability to 78% (40/51). Proximal and distal diameters of the graft-covering portion ranging between 30 and 46 mm would enable 10% graft oversizing in all but six patients. In 88% (45/51) the required minimum 10 mm distance between aortic valve annulus and coronary artery ostia was found. Mean distance between left and right coronary artery ostia and sinotubular junction was 2.6 ± 1.5 and 3.2 ± 1.7 mm, respectively.
CONCLUSIONS: Novel composite endovascular valved grafts may extend the application of transcatheter techniques to patients denied TAVI due to a concomitant ascending aneurysm. The location of coronary arteries in relation to the sinotubular junction must be addressed in designing these composite valve grafts.
© 2014 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2014        PMID: 24762037     DOI: 10.1111/jocs.12348

Source DB:  PubMed          Journal:  J Card Surg        ISSN: 0886-0440            Impact factor:   1.620


  5 in total

1.  Endovascular treatment of acute Type A aortic dissection-the Endo Bentall approach.

Authors:  Maximilian Kreibich; Bartosz Rylski; Stoyan Kondov; Julia Morlock; Johannes Scheumann; Fabian A Kari; Holger Schröfel; Matthias Siepe; Friedhelm Beyersdorf; Martin Czerny
Journal:  J Vis Surg       Date:  2018-04-04

Review 2.  Thoracic aortic aneurysm: unlocking the "silent killer" secrets.

Authors:  Ayman A Saeyeldin; Camilo A Velasquez; Syed Usman B Mahmood; Adam J Brownstein; Mohammad A Zafar; Bulat A Ziganshin; John A Elefteriades
Journal:  Gen Thorac Cardiovasc Surg       Date:  2017-12-04

3.  Combined Transapical Transcatheter Aortic Valve Replacement and Thoracic Endovascular Aortic Repair for Severe Aortic Stenosis and Arch Aneurysm.

Authors:  Yuanjia Zhu; Eric E Roselli; Jay J Idrees; Samir Kapadia; Lars G Svensson
Journal:  Aorta (Stamford)       Date:  2016-10-01

Review 4.  Fenestrated and Branched Aortic Grafts.

Authors:  Bartosz Rylski; Martin Czerny; Michael Südkamp; Maximilian Russe; Matthiase Siep; Friedhelm Beyersdorf
Journal:  Dtsch Arztebl Int       Date:  2015-11-27       Impact factor: 5.594

5.  Endovascular Treatment of the Ascending Aorta: is this the Last Frontier in Aortic Surgery?

Authors:  Eduardo Keller Saadi; Ana Paula Tagliari; Rui M S Almeida
Journal:  Braz J Cardiovasc Surg       Date:  2019-12-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.