Literature DB >> 24761701

The role of cardiac computed tomography in infants with congenital heart disease.

Orly Goitein, Yishay Salem, Jeffrey Jacobson, David Goitein, David Mishali, Ashraf Hamdan, Rafael Kuperstein, Elio Di Segni, Eli Konen.   

Abstract

BACKGROUND: Patients with complex congenital heart disease (CHD) have a high incidence of extracardiac vascular and non-vascular malformations. Those additional abnormalities may have an impact on the precise planning of surgical or non-surgical treatment.
OBJECTIVES: To assess the role of electrocardiography-gated CT-angiography (ECG-CTA) in the routine evaluation of CHD in neonates and infants particularly for the assessment of extracardiac findings.
METHODS: The study cohort comprised 40 consecutive patients who underwent trans-thoracic echocardiography (TTE) and ECG-CTA. TTE and ECG-gated CTA findings regarding extracardiac vascular structures, coronary arteries and airways were compared with surgical or cardiac catheterization findings. Scans were evaluated for image quality using a subjective visual scale (from 1 to 4). Effective radiation dose was calculated for each scan.
RESULTS: Median age was 28 +/- 88 days and mean weight 3.7 +/- 1.5 kg. Diagnostic quality was good or excellent (visual image score 3-4) in 39 of 40 scans (97.5%). ECG-CTA provided important additional information on extracardiac vascular structures and airway anatomy, complementing TTE in 75.6% of scans. Overall sensitivity of ECG-gated CTA for detecting extracardiac findings as compared with operative and cardiac catheterization findings was 97.6%. The calculated mean effective radiation dose was 1.4 +/- 0.07 mSv (range 1.014-2.3 mSv).
CONCLUSIONS: ECG-CTA is an accurate modality for demonstrating extracardiac structures in complex CHD. It provides important complementary information to TTE with regard to extracardiac vascular structures and coronary artery anatomy. This modality may obviate the need for invasive cardiac catheterization, thus exposing the patient to a much lower radiation dose.

Entities:  

Mesh:

Year:  2014        PMID: 24761701

Source DB:  PubMed          Journal:  Isr Med Assoc J            Impact factor:   0.892


  6 in total

1.  Evaluation of complex congenital heart disease in infants using low dose cardiac computed tomography.

Authors:  Jannika Dodge-Khatami; Dilachew A Adebo
Journal:  Int J Cardiovasc Imaging       Date:  2021-01-03       Impact factor: 2.357

2.  Evaluation of coronary artery variations using dual-source coronary computed tomography angiography in neonates with transposition of the great arteries.

Authors:  Yuko Odawara; Nobuko Kawamura; Yuzo Yamasaki; Joji Hashimoto; Shiro Ishikawa; Hiroshi Honda
Journal:  Jpn J Radiol       Date:  2019-01-02       Impact factor: 2.374

3.  Image quality and radiation dose of dual source high pitch computed tomography in pediatric congenital heart disease.

Authors:  Dmitrij Kravchenko; Christopher Hart; Stephan Garbe; Julian A Luetkens; Alexander Isaak; Narine Mesropyan; Mathieu Vergnat; Judith Leyens; Ulrike Attenberger; Daniel Kuetting
Journal:  Sci Rep       Date:  2022-06-15       Impact factor: 4.996

Review 4.  Illustrated Imaging Essay on Congenital Heart Diseases: Multimodality Approach Part I: Clinical Perspective, Anatomy and Imaging Techniques.

Authors:  Venkatraman Bhat; Vinay Belaval; Karthik Gadabanahalli; Vimal Raj; Sejal Shah
Journal:  J Clin Diagn Res       Date:  2016-05-01

5.  Integration of Computed Tomography and Three-Dimensional Echocardiography for Hybrid Three-Dimensional Printing in Congenital Heart Disease.

Authors:  Jordan Gosnell; Todd Pietila; Bennett P Samuel; Harikrishnan K N Kurup; Marcus P Haw; Joseph J Vettukattil
Journal:  J Digit Imaging       Date:  2016-12       Impact factor: 4.056

6.  In Vivo CT Direct Volume Rendering: A Three-Dimensional Anatomical Description of the Heart.

Authors:  Giuseppina Cutroneo; Daniele Bruschetta; Fabio Trimarchi; Alberto Cacciola; Maria Cinquegrani; Antonio Duca; Giuseppina Rizzo; Emanuela Alati; Michele Gaeta; Demetrio Milardi
Journal:  Pol J Radiol       Date:  2016-01-21
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.