Literature DB >> 24758679

Dose reduction of the female breast in chest CT.

Anna Seidenfuss1, Andreas Mayr, Matthias Schmid, Michael Uder, Michael M Lell.   

Abstract

OBJECTIVE: Organ-based tube current modulation has been shown to significantly reduce the radiation dose to the female breast in phantom studies. We sought to assess the proportions of female breast and glandular tissues that are within the range of organ-based tube current modulation in different age groups and whether these proportions could be optimized by clothing. The secondary objective of our study was to determine whether metal parts of brassieres cause artifacts that impair the diagnostic value. SUBJECTS AND METHODS: Five hundred seventy-eight female patients undergoing chest CT were included in this study. Two hundred nine patients were prospectively examined wearing a brassiere (group A), and the control patients (group B; n = 369) were scanned according to our previous standard without wearing a brassiere during CT. The two groups were subdivided according to cup size (A-E). For CT data acquisition, an angle-dependent tube current modulation, which reduces the tube current for anterior tube position to minimize direct exposure to anteriorly located organs, was used. The proportion of breast tissue and glandular tissue located within and outside the region of tube current reduction was assessed.
RESULTS: The results showed that 60.4% of total breast tissue and 67.1% of glandular tissue was inside the region of tube current reduction in group B; the proportions were significantly improved, to an average of 91.3% and 96%, respectively, in group A. Diagnostically relevant artifacts were introduced in none of the patients. Patients' age correlated with this effect, with higher rates of improvement in the older patient group. Angle-dependent tube current modulation was most effective in patients with cup size A while wearing a brassiere. In this group, 97.5% of breast tissue and 98.1% of glandular tissue was inside the region of tube current reduction. Women with a cup size of E had the largest effect of wearing a brassiere, increasing the rate of breast tissue that was affected by angle-dependent tube current modulation from 30.0% to 83.3% and that of glandular tissue from 31.8% to 90.0%.
CONCLUSION: We show that wearing a brassiere increases the percentage of breast tissue within the region of reduced tube current and, therefore, improves the performance of angle-dependent tube current modulation technique.

Entities:  

Mesh:

Year:  2014        PMID: 24758679     DOI: 10.2214/AJR.13.10541

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  3 in total

1.  Do we need 3D tube current modulation information for accurate organ dosimetry in chest CT? Protocols dose comparisons.

Authors:  Xochitl Lopez-Rendon; Guozhi Zhang; Walter Coudyzer; Wim Develter; Hilde Bosmans; Federica Zanca
Journal:  Eur Radiol       Date:  2017-05-19       Impact factor: 5.315

2.  Breast dose reduction for chest CT by modifying the scanning parameters based on the pre-scan size-specific dose estimate (SSDE).

Authors:  Masafumi Kidoh; Daisuke Utsunomiya; Seitaro Oda; Takeshi Nakaura; Yoshinori Funama; Hideaki Yuki; Kenichiro Hirata; Tomohiro Namimoto; Daisuke Sakabe; Masahiro Hatemura; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2016-10-07       Impact factor: 5.315

3.  A comparison of breast and lung doses from chest CT scans using organ-based tube current modulation (OBTCM) vs. Automatic tube current modulation (ATCM).

Authors:  Rick R Layman; Anthony J Hardy; Hyun J Kim; Ei Ne Chou; Maryam Bostani; Chris Cagnon; Dianna Cody; Michael McNitt-Gray
Journal:  J Appl Clin Med Phys       Date:  2021-05-03       Impact factor: 2.102

  3 in total