Literature DB >> 24757181

Calculation of limits for significant unidirectional changes in two or more serial results of a biomarker based on a computer simulation model.

Flemming Lund1, Per Hyltoft Petersen2, Callum G Fraser3, György Sölétormos4.   

Abstract

BACKGROUND: Reference change values (RCVs) were introduced more than 30 years ago and provide objective tools for assessment of the significance of differences in two consecutive results from an individual. However, in practice, more results are usually available for monitoring, and using the RCV concept on more than two results will increase the number of false-positive results. Therefore, a simple method is needed to interpret the significance of a difference when all available serial biomarker results are considered.
METHODS: A computer simulation model using Excel was developed. Based on 10,000 simulated data from healthy individuals, a series of up to 20 results from an individual was generated using different values for the within-subject biological variation plus the analytical variation. Each new result in this series was compared to the initial measurement result. These successive serial relative differences were computed to give limits for significant unidirectional differences with a constant cumulated maximum probability of both 95% (P < 0.05) and 99% (P < 0.01).
RESULTS: Factors used to multiply the first result from an individual were calculated to create the limits for constant cumulated significant differences. The factors were shown to become a simple function of the number of results and the total coefficient of variation.
CONCLUSIONS: To interpret unidirectional differences in two or more serial results of a biomarker, the limits for significances are easily calculated using the presented factors. The first result is multiplied by the appropriate factor for increase or decrease, which gives the limits for a significant difference.
© The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

Keywords:  Simulation models; biological variation; log-normal (Gaussian) distribution; monitoring; normal (Gaussian) distribution; reference change value; unidirectional differences

Mesh:

Substances:

Year:  2014        PMID: 24757181     DOI: 10.1177/0004563214534636

Source DB:  PubMed          Journal:  Ann Clin Biochem        ISSN: 0004-5632            Impact factor:   2.057


  4 in total

Review 1.  Acute Kidney Injury: Diagnostic Approaches and Controversies.

Authors:  Konstantinos Makris; Loukia Spanou
Journal:  Clin Biochem Rev       Date:  2016-12

2.  Interpretation of Biochemical Tests Using the Reference Change Value in Monitoring Adverse Effects of Oral Isotretinoin in 102 Ethnic Turkish Patients.

Authors:  Guler Bugdayci; Mualla Polat; Hamdi Oguzman; Havva Yasemin Cinpolat
Journal:  Lab Med       Date:  2016-06-26

Review 3.  Uncertainty in measurement: A review of the procedures for determining uncertainty in measurement and its use in deriving the biological variation of the estimated glomerular filtration rate.

Authors:  Ian Farrance; Tony Badrick; Robert Frenkel
Journal:  Pract Lab Med       Date:  2018-04-05

4.  Reference change values in concentrations of urinary and salivary biomarkers of exposure and mouth level exposure in individuals participating in an ambulatory smoking study.

Authors:  Oscar M Camacho; Johan Sommarström; Krishna Prasad; Anthony Cunningham
Journal:  Pract Lab Med       Date:  2016-05-17
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.